H7BX-A | Omron Dual Counter | IndMALL Automation https://www.googletagmanager.com/gtag/js?id=AW-11114891143
+91 79955 44066 sales@indmall.in

H7BX-A: Omron Dual Counter

Technical Specifications of Omron Dual Counter H7BX-A:

SpecValue
Function1 Stage Preset Counter, Total Preset Counter
Preset stages1 step
Rated Supply Voltage100 to 240 VAC 50/60 Hz
Count Range-99999 to 999999

Omron Dual Counter H7BX-A Technical Specifications:

SpecificationValue
Function1 Stage Preset Counter, Total Preset Counter
Preset Stages1 step
Rated Supply Voltage100 to 240 VAC 50/60 Hz
Operating Voltage Range85 to 110% of rated power supply voltage
Power Consumption9.6 VA max.
External power supply12 VDC (±10%) 100 mA
Count range-99999 to 999999
Max. counting speed30 Hz/5 kHz (switching) (ON/OFF ratio 1:1)
Minimum input signal width30 Hz: 16.7 ms 5 kHz: 0.1 ms
Counter Input modeIncrement (UP), decrement (DOWN), increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual inputs), or UP/DOWN C (quadrature inputs)), UP/DOWN D (command input), UP/DOWN E (individual inputs), UP/DOWN E (quadrature inputs))
Output modesN, F, C, R, K-1, P, Q, A, K-2, D, L
Counter One-shot output time0.01 to 99.99 s
Reset systemExternal (Minimum input signal width: 1 ms/20 ms selectable, manual and automatic reset (internal according to C, R, P and Q mode operation)
Input signalCP1, CP2, Reset 1, Reset 2, Key protect
Input methodNo-voltage (NPN)/Voltage input (PNP) selectable
No-voltage input (No-contact input)Short-circuit (ON) impedance: 1 kΩ max. (Leakage current (0 Ω): Approx. 12 mA) Residual voltage: 3 V max. Open circuit impedance: 100 kΩ min.
No-voltage input (Contact input)Use a contact which can adequately switch 5 mA at 10 V.
Voltage inputHight level: 4.5 to 30 VDC Low level: 0 to 2 VDC (Input resistance Approx. 4.7 kΩ)
Contact outputSPST-NO 3 A at 250 VAC/30 VDC, resistive load (cos phi=1) Minimum applicable load: 10 mA at 5 VDC (failure level:P reference value)
Solid-state outputNPN 30 VDC max., 100 mA max. Residual voltage 1.5 V max.DCCapacity value: Approx. 1 V Leakage current 0.1 mA max.
Display method7-segment backlit negative transmissive LCD
Display Digits6 digit
Prescaling function0.001 to 99.999
Decimal point adjustmentRightmost 3 digits
Memory backup methodsMethod: Non-volatile memory, Number of rewite: 100,000 operations min., Store data: 10 years min
Ambient temperature (Operating)-10 to 55 ℃ (with no icing)
Ambient temperature (Storage)-25 to 65 ℃ (with no icing)
Ambient humidity (Operating)25 to 85 % (with no condensation)
Insulation resistanceBetween current carrying terminals and exposed non-current carrying metal parts: 100 MΩ min. (at 500 VDC) Between non-continuous contacts: 100 MΩ min. (at 500 VDC)
Dielectric withstand voltageBetween current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between operating power circuit and input circuit: 2000 VAC 50/60 Hz 1 min Between control output, and power supply/input circuit: 2000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1000 VAC 50/60 Hz 1 min
Impulse withstand voltageBetween power terminals: 6 kV Between current carrying terminals and exposed non-current carrying metal parts: 6 kV
Noise immunityBetween power terminals: ±1.5 kV Between input terminals: ±600 V square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Static immunityMulfunction: 8 kV, Destruction: 15 kV
Vibration resistanceDestruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min
Shock ResistanceDestruction: 294 m/s2, 3 times each in 3 axes 6 directions Malfunction: 98 m/s2, 3 times each in 3 axes 6 directions
Degree of ProtectionCase front: IP54
External Connection MethodScrew terminal
Case ColorBlack (Munsell N1.5)
AccessoriesMounting Bracket, Terminal Cover
WeightApprox. 250 g
Mail Us for your needs in Omron Dual Counter, H7BX-A with budget-friendly prices. The Main Technical Parameters of H7BX-A include 30 Hz/5 kHz (switching) (ON/OFF ratio 1:1), -99999 to 999999, 12 VDC (±10%) 100 mA, 1 Stage Preset Counter, Total Preset Counter. Additionally, it provides 100 to 240 VAC 50/60 Hz, 85 to 110% of rated power supply voltage, 9.6 VA max.. Customize Your Experience with a Quote for your requirement of Omron Dual Counter. Experience the difference with our competitive pricing and superior support over other Suppliers.