+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

Omron H5CN-XANM AC100-240 Digital Timer

The Omron H5CN-XANM AC100-240 Timer operates within 85 to 110% of rated supply voltage and provides 1 time range of 0.01 to 99.99 s. It supports a Power ON delay output mode with External reset functions. This UP display timer timer features a 7-segment LED 4 digit display with 10 mm characters and 8 kV mulfunction static immunity. Designed for Flush mounting / Surface mounting, it connects through an 11-pin round socket and comes in a Light gray case. Manufactured by Omron, found under Omron Timers, this model belongs to the Omron H5CN Series.

BrandOmron
ProductTimers
Model NumberH5CN-XANM AC100-240

Omron H5CN-XANM AC100-240 Digital Timer - Technical Specifications

SpecificationValue
Rated supply voltage100 to 240 VAC (50/60 Hz)
Operating voltage range85 to 110% of rated supply voltage
Control output (Contact output)SPDT Resistive load: 3 A at 250 VAC (cosφ=1) Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value)
Connection method11-pin round socket
Mounting methodFlush mounting / Surface mounting
Power consumptionApprox. 12 VA (at 240 VAC)/Approx. 2.5 W (at 240 VAC)
Time ranges0.01 to 99.99 s
Input methodContact: Contact open and short-circuit input No-contact: Open-collector transistor ON/OFF input
Output modesN: Power ON delay
Reset systemExternal reset
Timer modeUP display timer (increments form 0 to the set time)
Display method7-segment LED 4 digit
Character height10 mm
Ambient temperature range-10 to 55 ℃ (with no icing)
Ambient humidity (Operating)-25 to 65 ℃ (with no icing)
Accuracy of operating timeReset start: ±0.005% ±0.03 s max. (The values are based on the set value.)
Setting errorReset start: ±0.005% ±0.03 s max. (The values are based on the set value.)
Influence of voltageReset start: ±0.005% ±0.03 s max. (The values are based on the set value.)
Influence of temperatureReset start: ±0.005% ±0.03 s max. (The values are based on the set value.)
Insulation resistanceBetween current carrying terminals and exposed non-current carrying metal parts: 100 MΩ min. (at 500 VDC) Between operating power circuit and control output circuit: 100 MΩ min. (at 500 VDC)
Dielectric strengthBetween current carrying terminals and exposed non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between operating power circuit and control output circuit: 2000 VAC 50/60 Hz 1 min
Impulse withstand voltageBetween operating power supply terminals: 6 kV Between current carrying terminals and exposed non-current carrying metal parts: 6 kV
Noise immunityBetween operating power supply terminals: ±2 kV Square-wave noise by noise simulator
Static immunityMulfunction: 8 kV
Vibration resistanceDestruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min
Shock resistanceDestruction: 300 m/s2, 3 times each in 6 directions Malfunction: 100 m/s2, 3 times each in 6 directions
Case colorLight gray (Munsell 5Y7/1)
Accessory (sold separately)Soft Cover: Y92A-48D Hard Cover: Y92A-48B Flush mounting adapter: Y92F-30
Ambient temperature range-10 to 55 ℃ (with no icing)
Ambient humidity range35 to 85%
Life expectancy (relay output)Electrical: 100,000 operations min. (3 A at 250 VAC resistive load) Mechanical: 10 million operations min.
Time ranges (Number of ranges)1
External reset and GateMinimum input signal width: 0.02 s Residual voltage: 2 V max.
Applicable socketP2CF-08, P2CF-08-E, P3G-08
WeightApprox. 110 g