H3FA-A DC5 | Omron 5V DC 1s Contact Timer | IndMALL https://www.googletagmanager.com/gtag/js?id=AW-11114891143
+91 79955 44066 sales@indmall.in

H3FA-A DC5: Omron 5V DC 1s Contact Timer

Technical Specifications of Omron 5V DC 1s Contact Timer H3FA-A DC5:

SpecValue
Rated Power Supply Voltage5 VDC Ripple 3% max.
Number of Time Ranges4
Operation ModePower ON-delay, Cumulative
Control Output TypeTime-limit: SPST-NO ,Time-limit: SPST-NC

Omron 5V DC 1s Contact Timer H3FA-A DC5 Technical Specifications:

SpecificationValue
Rated power supply voltage5 VDC Ripple 3% max.
Allowable voltage variable range90 to 110% of the power supply voltage
Power consumptionApprox. 230 mW
Number of time ranges4
Operation modePower ON-delay, Cumulative
Control output (Type)Time-limit: SPST-NO ,Time-limit: SPST-NC
Control output (Contact output)Resistive load: 3 A at 250 VAC Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value)
Operating resettingTime-limit operation/power-OFF resetting and external resetting, Integrating operation/power-OFF resetting and external resetting
Ambient temperature rangeOperating: -10 to 55 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing)
Ambient humidity rangeOperating: 35 to 85%
Accuracy of operating time±0.5% FS max. (±0.5% ±10 ms in a range of 1 s)
Setting error0 to +30% FS max. (at 20 ℃, rated voltage)
Reset time10 ms max.
Influence of voltage±2% FS max.
Influence of temperature±5% FS max. (±5% ±10 ms in a range of 1 s)
Insulation resistance100 MΩ min. (at 500 VDC)
Dielectric strengthBetween control output terminals and operating circuit: 1,500 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min
Vibration resistanceDestruction: 10 to 55 Hz, 0.375 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.25 mm single amplitude each in 3 directions for 10 min
Shock resistanceDestruction: 1,000 m/s2, 3 times each in 6 directions Malfunction: 100 m/s2, 3 times each in 6 directions
Life expectancy (relay output)Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load at 1800 operations/h) Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
Connecting methodPCB terminal
WeightApprox. 15 g
Send Your Inquiry for Omron 5V DC 1s Contact Timer, H3FA-A DC5 with cost-effective solutions. Essential Technical Specs of H3FA-A DC5 cover Approx. 15 g, PCB terminal, 100 MΩ min. (at 500 VDC), ±2% FS max., 10 ms max., Time-limit: SPST-NO ,Time-limit: SPST-NC, Power ON-delay, Cumulative & Approx. 230 mW. It also delivers 90 to 110% of the power supply voltage, 5 VDC Ripple 3% max. & 4. Capture the Best Deal with a Quote for your requirement of Omron 5V DC 1s Contact Timer. Our pricing and support are designed to exceed the standards of other Traders & Suppliers.