H3CR-F AC100-240/DC100-125: Omron Flicker OFF Start Mode Timer

Technical Specifications of Omron Flicker OFF Start Mode Timer H3CR-F AC100-240/DC100-125:

SpecValue
Rated power supply voltage100 to 240 VAC 50/60 Hz 100 to 125 VDC Ripple 20% max. (If power supply incorporates a single-phase full-wave rectifier)
Allowable voltage variable range85 to 110% of the power supply voltage
Power consumptionApprox. 10 VA (at 240 VAC) Approx. 2.1 W (at 240 VAC)
Operation start voltage10% max. of rated supply voltage

Omron Flicker OFF Start Mode Timer H3CR-F AC100-240/DC100-125 Technical Specifications:

SpecificationValue
Rated power supply voltage100 to 240 VAC 50/60 Hz 100 to 125 VDC Ripple 20% max. (If power supply incorporates a single-phase full-wave rectifier)
Allowable voltage variable range85 to 110% of the power supply voltage
Power ConsumptionApprox. 10 VA (at 240 VAC) Approx. 2.1 W (at 240 VAC)
Operation Start Voltage10% max. of rated supply voltage
Input Signals-
Input Method-
No Voltage Input-
Number of Times Ranges18
Opeation ModeFlicker OFF start
Control Output TypeTime-limit: DPDT
Control output (Contact output)Resistive load: 250 VAC 5 A (cosφ=1)/5 A at 30 VDC Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value)
Operating resettingTime-limit operation/Time-limit reset or Self-reset
Ambient temperature rangeOperating: -10 to 55 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing)
Ambient humidity rangeOperating: 35 to 85%
Accuracy of operating time±0.2% FS max. ±0.2% ±10 ms in a range of 1.2 s and 3 s
Setting error±5% FS ±50 ms max.
Influence of voltage±0.2% FS max. ±0.2% ±10 ms in a range of 1.2 s and 3 s
Influence of temperature±1% FS max. (±1% ±10 ms in a range of 1.2 s and 3 s)
Insulation resistance100 MΩ min. (at 500 VDC)
Dielectric strengthBetween current carrying metal parts and non-current carrying metal parts: 2,000 VAC 50/60 Hz 1 min Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz 1 min Between contacts of different polarity: 2,000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min
Impulse withstand voltageBetween power terminals: 5 kV Between current carrying terminals and exposed non-current carrying metal parts: 5 kV
Noise immunity±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Static immunityMulfunction: 8 kV, Destruction: 15 kV
Vibration resistanceDestruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min
Shock resistanceDestruction: 980 m/s2, 3 times each in 6 directions Malfunction: 98 m/s2, 3 times each in 6 directions
Life expectancy (relay output)Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1800 operations/h) Mechanical: 20 million operations min. (under no load at 1,800 operations/h)
Degree of protectionIP40 (panel surface)
Connecting method11-pin round socket
WeightApprox. 100 g
Call us for Omron Flicker OFF Start Mode Timer, H3CR-F AC100-240/DC100-125 at the best rates. Technical Attributes of H3CR-F AC100-240/DC100-125 are Flicker OFF start 100 to 240 VAC 50/60 Hz 100 to 125 VDC Ripple 20% max. (If power supply incorporates a single-phase full-wave rectifier) 85 to 110% of the power supply voltage. And It Delivers Approx. 10 VA (at 240 VAC) Approx. 2.1 W (at 240 VAC), 10% max. of rated supply voltage, 18.Unlock Exclusive Pricing with a Quote for your requirement of Omron Flicker OFF Start Mode Timer. Trust in our ability to provide more advantageous pricing and dedicated support beyond other other Dealers.