Omron G3PW-A220EU-C Solid-state Relay
Omron G3PW-A220EU-C is a single-phase power controller with a 20 A rated operational current and a 100 to 240 V rated operational voltage. Its operating voltage range is 85 to 264 V, and the supplied specification lists a 1 to 5 V control input. This version uses push-in and screw terminals and has a permissible I²t value of 400 A²s with a 5 kW heater load capacity. The specified operating-temperature limits are -15°C and 55°C, while the listed heater capacity reaches 5 kW. The G3PW-A220EU-C controller forms part of the G3PW series in the Solid state switching portfolio supplied through Omron automation components.

| Brand | Omron |
| Product | Solid State Relay |
| Model Number | G3PW-A220EU-C |
Omron G3PW-A220EU-C Solid-state Relay - Technical Specifications
| Specification | Value |
|---|---|
| Application | Power control |
| Number Of Phases | 1 |
| Terminal Type | Push-in, Screw |
| Rated Operational Voltage Ac | 100-240 V |
| Operating Voltage Range Ac | 85-264 V |
| Rated Operation Current Ie At Ac 1 | 20 A |
| Permissible I T Value | 400 A²s |
| Applicable Heater Capacity Ac1 Resistive Load | 5 kW |
| Supply Voltage Dc | 1-5 V |
| Maximum Operating Temperature | 55 °C |
| Minimum Operating Temperature | -15 °C |
The Omron G3PW-A220EU-C Solid State Relay is specified as a single-phase power controller with a 20 A rated operational current. Its rated operational voltage is 100 to 240 V and the operating range is 85 to 264 V. The supplied data lists a 1 to 5 V control input and a combined push-in and screw terminal arrangement. Permissible I²t is 400 A²s, while the applicable heater load capacity is 5 kW. The operating-temperature limits are -15°C and 55°C. Unlike the EC-FLK rows in the same G3PW group, heater burnout detection, constant-current control, and Serial RS-485 are not populated in this row, so they are not attributed to this model here.
The G3PW-A220EU-C therefore centers on the listed 20 A current class, 100 to 240 V rated operation, 85 to 264 V operating window, 1 to 5 V control signal, 400 A²s permissible I²t, and 5 kW heater-capacity figure. Its push-in and screw terminal entry is one of the clearest supplied differences from the EU-S version, which is listed with screw terminals. Both models share the same basic voltage, current, control-input, I²t, heater-capacity, and temperature values in the source. For that closely related screw-terminal option within the same G3PW series, review G3PW-A220EU-S.