Omron E2K-F10MC2 2M Proximity Sensor
Omron E2K-F10MC2 2M is a flat unshielded capacitive proximity sensor with a 10 mm sensing distance and a 0 to 7.5 mm setting distance. It uses a DC 3-wire NPN output with NC operation, a pre-wired 2 m cable, and a 12 to 24 VDC supply. Conductors and dielectrics are the specified detectable objects, with a 50 × 50 × 1 mm standard sensing object. Response frequency is 100 Hz, current consumption is 10 mA max. at 24 VDC, control-output current is 100 mA max., and differential travel is 15% max. A red detection indicator, reverse-polarity protection, surge suppression, and IP66 protection are specified. The E2K-F10MC2 2M is listed under flat capacitive sensors from Omron industrial sensors.

| Brand | Omron |
| Product | Proximity Sensors |
| Model Number | E2K-F10MC2 2M |
Omron E2K-F10MC2 2M Proximity Sensor - Technical Specifications
| Specification | Value |
|---|---|
| Sensor | Flat, Capacitive |
| Sensing Distance | 10 mm |
| Setting Distance | 0 to 7.5 mm |
| Output Configuration | DC 3-wire NPN |
| Operation Mode | NC |
| Connection | Pre-wired 2 M Cable |
| Differential Travel | 15% max. of sensing distance |
| Detectable Object | Conductors and dielectrics |
| Standard Sensing Object | 50 × 50 × 1 mm |
| Response Frequency | 100 Hz |
| Current Consumption | 10 mA max. at 24 VDC |
| Control Output Load Current | 100 mA max. (at 30 VDC) |
| Indicator | Detection indicator (red) |
| Protection Circuit | Reverse polarity protection, Surge suppressor |
| Ambient Temperature Range | Operating/Storage: −10 to 55°C (with no icing or condensation) |
| Ambient Humidity Range | Operating/Storage: 35% to 95% |
| Material | Heat-resistant ABS |
| Degree Of Protection | IP66 |
| Weight | Approx. 35 g |
The Omron E2K-F10MC2 2M Proximity Sensor uses a flat unshielded capacitive sensing body with a 10 mm sensing distance and a 0 to 7.5 mm setting distance. It provides a DC 3-wire NPN output with NC operation through a pre-wired 2 m cable and operates from 12 to 24 VDC. Conductors and dielectrics are the specified detectable objects, with a 50 × 50 × 1 mm standard sensing object. Response frequency is 100 Hz, current consumption is 10 mA max. at 24 VDC, control-output current is 100 mA max. at 30 VDC, and differential travel is 15% max. of sensing distance. A red detection indicator, reverse-polarity protection, and surge suppression are specified.
Environmental limits for the E2K-F10MC2 cover -10 to 55°C for operation and storage, with humidity from 35% to 95%. Heat-resistant ABS is listed as the construction material, and IP66 is the specified protection level. A red indicator, reverse-polarity protection, and surge suppression are listed. Control-output current is 100 mA max. at 30 VDC. The 10 mm sensing distance and 0 to 7.5 mm setting range are paired with NPN NC switching and the pre-wired 2 m cable. For another unshielded capacitive E2K sensor using a 2 m cable and NPN output but an 8 mm sensing distance with NO operation, see E2K-X8ME1 2M.