Omron E2B-M30LN30-WP-C2 2M Proximity Sensor
Omron E2B-M30LN30-WP-C2 2M is specified with an M30 cylindrical unshielded body, 30 mm sensing distance, 0 to 22.5 mm setting range, and long housing. Its DC 3-wire NPN NC output is wired through a pre-wired 2 m cable and operates from 10 to 30 VDC. Response frequency is rated at 100 Hz. Control output reaches 200 mA max. at 30 VDC max., while the maximum voltage drop is 2 V. Ferrous metal is the sensing object, referenced with a 90 × 90 × 1 mm standard sensing object. View the E2B-M30LN30-WP-C2 2M among NPN proximity sensors available from Omron Automation Products.

| Brand | Omron |
| Product | Proximity Sensors |
| Model Number | E2B-M30LN30-WP-C2 2M |
Omron E2B-M30LN30-WP-C2 2M Proximity Sensor - Technical Specifications
| Specification | Value |
|---|---|
| Sensor | Inductive |
| Housing Shape | Cylindrical |
| Size | M30 |
| Mounting type | Unshielded |
| Sensing Distance | 30 mm |
| Setting Distance | 0 to 22.5 mm |
| Output configuration | DC, 3-wire, NPN |
| Operation Mode | NC |
| Body Length | Long body |
| Connection Method | Pre-wired 2M Cable |
| Detectable Object | Ferrous metal |
| Standard Sensing Object | 90 × 90 × 1 mm |
| Response Frequency | 100 Hz |
| Power Supply Voltage | 10 to 30 VDC |
| Protection Circuit | Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection |
| Ambient Temperature Range | Operation and storage : -25 to 70ºC |
| Degree of Protection | IP67(IEC60529), EMC (EN60947-5-2) |
| Control Output | 200 mA max. (30 VDC max.), 2 V max. |
| Indicators | Operation indicator (Yellow LED) |
| Materials | Brass-nickel plated, PBT, Standard cable is 4 mm dia. PVC, Brass-nickel plated, Zinc-plated iron. |
| Weight | Approx. 210 g |
The Omron E2B-M30LN30-WP-C2 2M Proximity Sensor uses an M30 cylindrical unshielded sensing body with a 30 mm range, 0 to 22.5 mm setting distance, and long housing. Its electrical configuration is DC 3-wire NPN normally closed through a pre-wired 2 m cable, operating from 10 to 30 VDC. Response frequency is rated at 100 Hz. Control output is specified at 200 mA max. at 30 VDC max. with a maximum 2 V voltage drop. Ferrous metal is listed as the sensing object, while the standard sensing object measures 90 × 90 × 1 mm. A yellow operation indicator is provided together with reverse-polarity, surge, and short-circuit protection.
The E2B-M30LN30-WP-C2 is specified for operation and storage from -25 to 70°C. IP67 according to IEC 60529 and EMC according to EN60947-5-2 are stated. Construction information includes brass-nickel-plated material, PBT, zinc-plated iron, and a standard 4 mm PVC cable. Its long M30 body provides the stated 30 mm sensing distance, while the fixed lead supports direct wiring for NPN NC applications. For an M12 E2B model with an 8 mm sensing distance and pre-wired PNP output, see E2B-M12LN08-WP-B2 2M.