Omron E2B-M12KS04-M1-B2 Proximity Sensor

Omron E2B-M12KS04-M1-B2 uses a cylindrical M12 shielded inductive sensing body with a 4 mm sensing distance, a 0 to 3.2 mm setting distance, and short-body construction. It provides a DC 3-wire PNP output with NC operation through an M12 connector and operates from 10 to 30 VDC. Ferrous metal is specified for detection, with a 12 × 12 × 1 mm standard sensing object. Response frequency is 1,000 Hz, control output is rated 200 mA max. at 30 VDC max., and voltage drop is 2 V max. A yellow operation indicator and IP67 protection are listed. The E2B-M12KS04-M1-B2 is included among shielded proximity sensors from Omron industrial sensors.

Omron E2B-M12KS04-M1-B2 Proximity Sensor
BrandOmron
ProductProximity Sensors
Model NumberE2B-M12KS04-M1-B2

Omron E2B-M12KS04-M1-B2 Proximity Sensor - Technical Specifications

SpecificationValue
SensorInductive
Housing ShapeCylindrical
SizeM12
Mounting typeShielded
Sensing Distance4 mm
Setting Distance0 to 3.2 mm
Output configurationDC, 3-wire, PNP
Operation ModeNC
Body LengthShort body
Connection MethodM12 Connector
Detectable ObjectFerrous metal
Standard Sensing Object12 × 12 × 1 mm
Response Frequency1,000 Hz
Power Supply Voltage10 to 30 VDC
Protection CircuitOutput reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection
Ambient Temperature RangeOperation and storage : -25 to 70ºC
Degree of ProtectionIP67(IEC60529), EMC (EN60947-5-2)
Control Output200 mA max. (30 VDC max.), 2 V max.
IndicatorsOperation indicator (Yellow LED)
MaterialsBrass-nickel plated, PBT, Standard cable is 4 mm dia. PVC, Brass-nickel plated, Zinc-plated iron.
WeightApprox. 35 g

The Omron E2B-M12KS04-M1-B2 Proximity Sensor uses a cylindrical M12 shielded inductive sensing body with a 4 mm sensing distance, a 0 to 3.2 mm setting distance, and short-body construction. It provides a DC 3-wire PNP output with NC operation through an M12 connector and operates from 10 to 30 VDC. Ferrous metal is the specified detectable object, with a 12 × 12 × 1 mm standard sensing object. Response frequency is 1,000 Hz. Control output is rated 200 mA max. at 30 VDC max., while voltage drop is 2 V max. A yellow operation indicator is provided with output reverse-polarity, power-source reverse-polarity, surge suppression, and short-circuit protection.

Operating and storage limits for the E2B-M12KS04-M1-B2 are -25 to 70°C. IP67 under IEC 60529 and EMC under EN60947-5-2 are listed. Nickel-plated brass, PBT, zinc-plated iron, and the standard 4 mm diameter PVC cable specification are included among the construction details. The short-body M12 arrangement combines shielded 4 mm sensing with PNP NC switching and connector termination. Ferrous metal is the stated target for the sensing data and selection. For another shielded PNP NC E2B model using an M8 body, 2 mm sensing distance, and a pre-wired 2 m cable, see E2B-S08KS02-WP-B2 2M.