Omron D4NS-1AF is a 1-conduit safety door switch designed to monitor protective doors and movable guards on industrial machinery. It uses slow-action 1NC/1NO contacts for guard-position switching, while a Type 2 low-level coded interlock provides the mechanical interface between the protective door and safety circuit. The direct opening mechanism provides 60 N minimum force on standard versions with 10 mm minimum travel. IP67 enclosure protection supports industrial installations, and the switch operates at guard movement speeds from 0.05 to 0.5 m/s. The D4NS-1AF belongs to the D4NS series within the safety interlock switch range from Omron machine safety products.

BrandOmron
Product TypeSafety Door Switch
Model NumberD4NS-1AF

Omron D4NS-1AF Safety Door Switch - Technical Specifications

SpecificationValue
Type1-Conduit type
Contact configurationSlow-action, 1NC/1NO
Interlock typeType 2
Coding levelLow level coded
Degree of protectionIP67
Operating speed0.05 to 0.5 m/s
Direct opening force<Standard type> 60 N min.; <High pull-force type> 80 N min.
Direct opening travel10 mm min.
Contact resistance25 mΩ max.
Rated insulation voltage (Ui)300 V
Rated frequency50/60 Hz
Insulation resistance100 MΩ min.
Contact gap2 × 2 mm min
Vibration resistanceMalfunction: 10 to 55 Hz, 0.75 mm single amplitude
Shock resistanceDestruction: 1,000 m/s2 min. Malfunction: 300 m/s2 min
Ambient operating temperature−30 to 70°C (with no icing)
Ambient operating humidity95% max
WeightApprox. 96 g

The Omron D4NS-1AF Safety Door Switch combines a 1-conduit construction with slow-action 1NC/1NO contacts for protective-door position monitoring. Its Type 2 low-level coded interlock provides mechanical guard detection, while IP67 enclosure protection supports industrial machine installations. The switch operates at speeds from 0.05 to 0.5 m/s. Standard versions provide 60 N minimum direct opening force, while high pull-force versions provide 80 N minimum. Direct opening travel is specified at 10 mm minimum, supporting mechanical contact separation when the associated protective guard is operated.

Electrical characteristics include 25 mΩ maximum contact resistance, a 300 V rated insulation voltage, 100 MΩ minimum insulation resistance and a 2 × 2 mm minimum contact gap. Rated frequency is 50/60 Hz. Malfunction vibration resistance covers 10 to 55 Hz at 0.75 mm single amplitude. Shock resistance reaches 1,000 m/s² minimum for destruction and 300 m/s² minimum for malfunction. The specified ambient operating temperature extends from −30 to 70°C with no icing, while humidity is rated up to 95%. Approximate. Its 1NC/1NO arrangement provides normally closed and normally open switching functions for guard monitoring. For a related 1-conduit D4NS model using slow-action 2NC contacts, the D4NS-1BF provides a different contact configuration within the same family.