Omron D4N-9125 Limit Switch
Omron D4N-9125 combines a metal lever and metal roller with 1NC/1NO snap-action switching. This version uses an M12 connector rather than a conduit entry and supports actuator speeds from 1 to 500 mm/s. The source specifies IP67 protection, 25 mΩ maximum contact resistance, 100 MΩ minimum insulation resistance, and a 300 V rated insulation voltage. The D4N-9125 is part of the D4N Series within the metal roller lever switch range from Omron switching components. Its all-metal actuator distinguishes it from the resin roller-lever D4N-9120.

| Brand | Omron |
| Product | Limit Switch |
| Model Number | D4N-9125 |
Omron D4N-9125 Limit Switch – Technical Specifications
| Specification | Value |
|---|---|
| Contact Form | 1NC/1NO |
| Shock Resistance | Destruction 1,000 m/s2 min. Malfunction 300 m/s2 min. |
| Degree Of Protection | IP67 |
| Insulation Resistance | 100 MΩ min. |
| Actuator | Roller lever (metal lever, metal roller) |
| Vibration Resistance | Malfunction 10 to 55 Hz, 0.75 mm single amplitude |
| Operating Mechanism | Snap-action |
| Conduit Size Conduit Openings | 1-conduit,M12 connector |
| Operating Speed | 1 to 500 mm/s |
| Operating Frequency | 30 operations/minute max. |
| Contact Resistance | 25 mΩ max. |
| Rated Insulation Voltage Ui | 300 V |
| Rated Frequency | 50/60 Hz |
| Ambient Operating Temperature | −30 to 70°C (with no icing) |
| Ambient Operating Humidity | 95% max |
| Weight | Approx. 82 g (D4N-1120) Approx. 99 g (D4N-6120) |
The Omron D4N-9125 Limit Switch uses a metal lever and metal roller with 1NC/1NO snap-action contacts. Its M12 connector provides the electrical interface, separating this configuration from similar D4N models that use G1/2 or M20 conduit entries. The actuator operates over a speed range from 1 to 500 mm/s, with a maximum switching frequency of 30 operations per minute. The source specifies 25 mΩ maximum contact resistance, 100 MΩ minimum insulation resistance, and a 300 V rated insulation voltage at 50/60 Hz. IP67 protection is also provided.
The switch operates from -30 to 70°C with relative humidity up to 95%. Malfunction vibration resistance covers 10 to 55 Hz at 0.75 mm single amplitude, while destructive and malfunction shock resistance are specified at least at 1,000 and 300 m/s² respectively. Since contact form, action type, connector, and electrical values closely match the D4N-9120, actuator construction is the clearest difference: this version uses both a metal lever and metal roller. For the corresponding resin lever and resin roller model, see the D4N-9120.