+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

Omron D4N-6C32 Limit Switch

Omron D4N-6C32 uses a roller plunger with 2NC/1NO slow-action contacts and a two-conduit G1/2 connection. The two-conduit format is the clearest physical difference from the otherwise similar single-conduit D4N plunger configurations. Operating speed is specified from 1 to 500 mm/s, with up to 30 operations per minute. IP67 protection, 25 mΩ maximum contact resistance, and 100 MΩ minimum insulation resistance are provided. The D4N-6C32 sits within the D4N Series and the 2-conduit roller plunger switch range from Omron switching components, combining three contacts with dual conduit access.

Omron D4N-6C32 Limit Switch
BrandOmron
ProductLimit Switch
Model NumberD4N-6C32

Omron D4N-6C32 Limit Switch – Technical Specifications

SpecificationValue
Contact Form2NC/1NO
Shock ResistanceDestruction 1,000 m/s2 min. Malfunction 300 m/s2 min.
Degree Of ProtectionIP67
Insulation Resistance100 MΩ min.
ActuatorRoller plunger
Vibration ResistanceMalfunction 10 to 55 Hz, 0.75 mm single amplitude
Operating MechanismSlow-action
Conduit Size Conduit Openings2-conduit,G1/2
Operating Speed1 to 500 mm/s
Operating Frequency30 operations/minute max.
Contact Resistance25 mΩ max.
Rated Insulation Voltage Ui300 V
Rated Frequency50/60 Hz
Ambient Operating Temperature−30 to 70°C (with no icing)
Ambient Operating Humidity95% max
WeightApprox. 82 g (D4N-1120); Approx. 99 g (D4N-6120)

The Omron D4N-6C32 Limit Switch combines a roller plunger with 2NC/1NO slow-action contacts and a two-conduit G1/2 connection. The dual-conduit format is the major construction difference from D4N-4C32, even though both use three contacts and the same roller-plunger actuator style. Mechanical operating speed ranges from 1 to 500 mm/s and maximum frequency is 30 operations per minute. IP67 protection, 25 mΩ maximum contact resistance, 100 MΩ minimum insulation resistance, and 300 V rated insulation voltage at 50/60 Hz are specified.

The operating range is -30 to 70°C with relative humidity up to 95%. Malfunction vibration resistance covers 10 to 55 Hz at 0.75 mm single amplitude. Shock resistance is at least 1,000 m/s² for destruction and 300 m/s² for malfunction. For model selection, the two G1/2 conduit entries should therefore be considered together with the 2NC/1NO contact arrangement. If only one conduit entry is required while keeping the roller plunger and three-contact slow-action configuration, see the D4N-4C32 model.