Omron D4C-3402 Limit Switch
Omron D4C-3402 features a 12 mm × 4.4 mm sintered stainless steel roller plunger, SPDT contacts, and a 4 A at 30 VDC rating. A four-core 3 m VCTF cable is already connected to the switch, while IP67 protection and a specified operating range of -10 to 70°C form part of its enclosure and operating specifications. Mechanical durability is listed at 10 million operations. The D4C-3402 belongs to the D4C Series within the roller plunger limit switch range from Omron switching products, with its 3 m cable and standard roller plunger distinguishing it from cross-roller and lever versions.

| Brand | Omron |
| Product | Limit Switch |
| Model Number | D4C-3402 |
Omron D4C-3402 Limit Switch – Technical Specifications
| Specification | Value |
|---|---|
| Shape Structure | General-purpose Limit switches |
| Ctuator | Roller plunger 12 dia. x 4.4 Sintered stainless steel roller |
| Contact Form | SPDT |
| Electrical Ratings | 4 A at 30 VDC |
| Load | General load |
| Ambient Temperature | Operating: -10 to 70 ℃ (with no icing) |
| Ambient Humidity | 35 to 95% RH |
| Shock Resistance | Destruction: 1,000 m/s 2 max. Malfunction: 500 m/s 2 max. |
| Degree Of Protection | IP67 |
| Contact Resistance Initial Value | 300 mΩ max. |
| Durability | Electrical: 200,000 operations min. (5 A at 125 VAC) Mechanical: 10 million operations min. |
| Cable Specifications | VCTF, 4 cores, 3 m Nominal sectional area: 0.75 mm 2 Diameter: 7.6 dia. |
The Omron D4C-3402 Limit Switch uses a conventional roller plunger instead of the cross-roller or lever arrangements found on several nearby D4C models. The actuator consists of a 12 mm × 4.4 mm sintered stainless steel roller and works with an SPDT contact configuration rated at 4 A at 30 VDC. The switch is supplied with a four-core 3 m VCTF cable having a nominal conductor section of 0.75 mm² and a diameter of 7.6 mm. IP67 protection is specified, together with an operating temperature of -10 to 70°C and 35 to 95% relative humidity.
Mechanical life is listed at 10 million operations minimum, and maximum contact resistance is 300 mΩ. The shock specification is 1,000 m/s² maximum for destruction and 500 m/s² maximum for malfunction. Unlike the D4C-3203, which changes roller orientation for directional actuation, this model retains a standard roller-plunger configuration. That actuator difference is one of the clearest ways to select between these two otherwise similar 30 VDC, 3 m cable versions. For a direct comparison with the cross-roller configuration, see the D4C-3203 model.