Omron D4C-1601 is a general-purpose limit switch with a 10 mm stainless steel pin plunger for direct machine position detection. The straight actuator suits stops, slides, and moving parts that approach the switch head-on, while the SPDT contact form provides changeover switching for general loads. Electrical ratings of 5 A at 250 VAC and 4 A at 30 VDC support common control circuits, with IP67 protection for the enclosed switch body. The D4C-1601 belongs to the D4C Series within the pin plunger limit switch range from Omron control products for direct travel and end-position sensing where straight plunger contact and SPDT switching are required.

| Brand | Omron |
| Product | Limit Switch |
| Model Number | D4C-1601 |
Omron D4C-1601 Limit Switch – Technical Specifications
| Specification | Value |
|---|---|
| Shape Structure | General-purpose Limit switches |
| Ctuator | Pin plunger 10 dia. Stainless steel plunger |
| Contact Form | SPDT |
| Electrical Ratings | 5 A at 250 VAC/ 4 A at 30 VDC |
| Load | General load |
| Inrush Current | NC: 20 A max. NO: 10 A max. |
| Ambient Temperature | Operating: -10 to 70 ℃ (with no icing) |
| Ambient Humidity | 35 to 95% RH |
| Pollution Degree | 3 (EN60947-5-1) |
| Shock Resistance | Destruction: 1,000 m/s 2 max. Malfunction: 500 m/s 2 max. |
| Classification Of Protection Against Electric Shock | Class I (with earth wire) |
| Degree Of Protection | IP67 |
| Permissible Operating Speed | Electrical: 30 operations / 1 minute max. Mechanical: 120 operations / 1 minute max. |
The Omron D4C-1601 Limit Switch uses a 10 mm stainless steel pin plunger for direct mechanical position detection. The straight actuator suits stops, slides, and moving parts that approach the sensing point head-on, while the SPDT contact form provides changeover switching for general loads. Electrical ratings are 5 A at 250 VAC and 4 A at 30 VDC, with inrush capability of 20 A maximum on the NC side and 10 A maximum on the NO side. IP67 protection covers the enclosed switch body. The model operates from -10 to 70°C with 35 to 95% relative humidity.
The D4C-1601 is specified for up to 120 mechanical operations and 30 electrical operations per minute. It is listed for pollution degree 3 under EN60947-5-1 and as Class I with an earth wire. Destructive shock resistance reaches 1,000 m/s² maximum, while malfunction shock resistance reaches 500 m/s² maximum. These characteristics suit direct end-position sensing where the moving target presses axially into a stainless steel plunger. The pin plunger is the main mechanical distinction when comparing this version with cross-roller models in the same D4C group. For a related D4C model using a cross roller plunger with the same electrical ratings and operating-frequency values, see the D4C-1603 model.