Technical Specifications of Delta Alarm Outputs Temperature Controller DT360RA-0200:

SpecValue
Panel Size (W×H)9696 1/4 DIN W96 × H96mm
Input Voltage80 ~ 260Vac 50/60Hz; 24Vac 50/60Hz ±10%; 24 Vdc ±10%
Power Consumption8VA max.
Display MethodLCD display. Process value (PV): Yellow color, Set point (SV): Green color

Delta Alarm Outputs Temperature Controller DT360RA-0200 Technical Specifications:

SpecificationValue
Panel Size (W×H)9696 1/4 DIN W96 × H96mm
Input Voltage80 ~ 260Vac 50/60Hz; 24Vac 50/60Hz ±10%; 24 Vdc ±10%
Power Consumption8VA max.
Display MethodLCD display. Process value (PV): Yellow color, Set point (SV): Green color
Alarm Output TypeRelay output: Max. load 250Vac, 3A resistive load
Display Accuracy0 or 1 digit to the right of the decimal point (selectable)
Sampling RateAnalog input: 0.1 sec/ per scan; Thermocouple or Platinum RTD: 0.1 sec/per scan
Control ModePID, PID program control (Ramp/Soak control), FUZZY, Self-tuning, Manual and On/FF
Sensor TypeThermocouple: K, J, T, E, N, R, S, B, L, U, TXK (Thermal couple measuring location are not intended to be directly connected to the MAINS supply.) 3-wire Platinum RTD: Pt100, JPt100 Resistance: Cu50, Ni120 Analog input: 0 ~ 5Vdc, 0 ~ 10Vdc, 0 ~ 20mA, 4 ~ 20mA, 0 ~ 50mVdc
Control OutputRelay output: Max. load 250Vac, 5A resistive load Voltage pulse output: 12Vdc, Max. output current 40mA Current output: DC 4 ~ 20m A output (Load resistance: Max. 500Ω) Analog voltage output: 0 ~ 10Vdc
Vibration Resistance10 to 55Hz, 10m/s2 for 10min, each in X, Y and Z directions
Shock ResistanceMax. 300m/ s2 , 3 times in each 3 axes, 6 directions
Ambient Temperature0°C ~ +50°C
Storage Temperature-20°C ~ +65°C
AltitudeMax. 2000m
Relative Humidity35% ~ 80% RH(non-condensing)
Panel protection levelIP66
Mail Us for your needs in Delta Alarm Outputs Temperature Controller, DT360RA-0200 with budget-friendly prices. The Main Technical Parameters of DT360RA-0200 include 0 or 1 digit to the right of the decimal point (selectable), Analog input: 0.1 sec/ per scan; Thermocouple or Platinum RTD: 0.1 sec/per scan, Relay output: Max. load 250Vac, 3A resistive load , LCD display. Process value (PV): Yellow color, Set point (SV): Green color . Additionally, it provides 8VA max., 80 ~ 260Vac 50/60Hz; 24Vac 50/60Hz ±10%; 24 Vdc ±10%, 9696 1/4 DIN W96 × H96mm. Customize Your Experience with a Quote for your requirement of Delta Alarm Outputs Temperature Controller. Experience the difference with our competitive pricing and superior support over other Suppliers.