DT360RA-0200: Delta Alarm Outputs Temperature Controller
Technical Specifications of Delta Alarm Outputs Temperature Controller DT360RA-0200:
Spec | Value |
---|---|
Panel Size (W×H) | 9696 1/4 DIN W96 × H96mm |
Input Voltage | 80 ~ 260Vac 50/60Hz; 24Vac 50/60Hz ±10%; 24 Vdc ±10% |
Power Consumption | 8VA max. |
Display Method | LCD display. Process value (PV): Yellow color, Set point (SV): Green color |
Delta Alarm Outputs Temperature Controller DT360RA-0200 Technical Specifications:
Specification | Value |
---|---|
Panel Size (W×H) | 9696 1/4 DIN W96 × H96mm |
Input Voltage | 80 ~ 260Vac 50/60Hz; 24Vac 50/60Hz ±10%; 24 Vdc ±10% |
Power Consumption | 8VA max. |
Display Method | LCD display. Process value (PV): Yellow color, Set point (SV): Green color |
Alarm Output Type | Relay output: Max. load 250Vac, 3A resistive load |
Display Accuracy | 0 or 1 digit to the right of the decimal point (selectable) |
Sampling Rate | Analog input: 0.1 sec/ per scan; Thermocouple or Platinum RTD: 0.1 sec/per scan |
Control Mode | PID, PID program control (Ramp/Soak control), FUZZY, Self-tuning, Manual and On/FF |
Sensor Type | Thermocouple: K, J, T, E, N, R, S, B, L, U, TXK (Thermal couple measuring location are not intended to be directly connected to the MAINS supply.) 3-wire Platinum RTD: Pt100, JPt100 Resistance: Cu50, Ni120 Analog input: 0 ~ 5Vdc, 0 ~ 10Vdc, 0 ~ 20mA, 4 ~ 20mA, 0 ~ 50mVdc |
Control Output | Relay output: Max. load 250Vac, 5A resistive load Voltage pulse output: 12Vdc, Max. output current 40mA Current output: DC 4 ~ 20m A output (Load resistance: Max. 500Ω) Analog voltage output: 0 ~ 10Vdc |
Vibration Resistance | 10 to 55Hz, 10m/s2 for 10min, each in X, Y and Z directions |
Shock Resistance | Max. 300m/ s2 , 3 times in each 3 axes, 6 directions |
Ambient Temperature | 0°C ~ +50°C |
Storage Temperature | -20°C ~ +65°C |
Altitude | Max. 2000m |
Relative Humidity | 35% ~ 80% RH(non-condensing) |
Panel protection level | IP66 |
Mail Us for your needs in Delta Alarm Outputs Temperature Controller, DT360RA-0200 with budget-friendly prices. The Main Technical Parameters of DT360RA-0200 include 0 or 1 digit to the right of the decimal point (selectable), Analog input: 0.1 sec/ per scan; Thermocouple or Platinum RTD: 0.1 sec/per scan, Relay output: Max. load 250Vac, 3A resistive load
, LCD display. Process value (PV): Yellow color, Set point (SV): Green color . Additionally, it provides 8VA max., 80 ~ 260Vac 50/60Hz; 24Vac 50/60Hz ±10%; 24 Vdc ±10%, 9696 1/4 DIN W96 × H96mm. Customize Your Experience with a Quote for your requirement of Delta Alarm Outputs Temperature Controller. Experience the difference with our competitive pricing and superior support over other Suppliers.