Technical Specifications of Delta 3-Position Operation Switch HMI DOP-H07S425

SpecValue
Display Size and Type7" Widescreen TFT LCD
Color65536 colors
Resolution (Pixels)800 x 480
Back LightLED Back Light

Delta 3-Position Operation Switch HMI DOP-H07S425 Technical Specifications:

SpecificationValue
Display Size and Type7" Widescreen TFT LCD
Color65536 colors
Resolution (Pixels)800 x 480
Back LightLED Back Light
Luminance (cd/m2 )450
Back Light Life (Hour)*120,000
MCU400 MHz
Flash ROM (Bytes)128 MB
RAM (Bytes)64 MB
Backup Memory (Bytes)16 MB
BuzzerMulti-Tone Frequency(2K ~ 4K Hz)/ 80dB
EthernetN/A
USB1 USB Client Ver 2.0
SDSD card (supports SDHC)
Serial COM PortRS-422 / RS-485(Note 2
Cable Length & TypeEnd of Model Name: 5 - 5 m End of Model Name: A - 10 m
Emergency StopB-contact: 2 Rated voltage: DC 30V Maximum rated current: 1A Minimum allowable load: DC 5V/1 mA Complies with IEC60947-5-1, EN60947-5-1, IEC60947-5-5, EN60947-5-5, UL 508, and CSA C22.2 No.14, GB 14085.5
3-Position Operation SwitchA-contact: 1 Rated voltage: DC 30V Maximum rated current: 700 mA Minimum allowable load:DC 3 V/5mA Complies with EN/IEC60947-5-8, IEC60947-5-1, EN60947-5-1, JIS C8201-5-1, UL508, and CSA C22.2 NO. 14 Applicable standards for use with ISO12100-1, -2/EN12100-1, -2, IEC60204-1/EN60204-1, ISO11161/prEN11161, ISO10218/EN775, ANSI/RIA R15.06, ANSI B11.19
Perpetual Calendar (RTC)Built-in
Cooling MethodNatural cooling
Safety ApprovalCE
Waterproof Level of Panel DisplayIP55
Operation Voltage*3DC +24V (±15%) (with built-in isolated power circuit)(Note2)
Voltage EnduranceAC500V for 1 minute (between charging (DC24V terminal) and FG terminals)
Power Consumption*55.6W
Backup Battery3V lithium battery CR2450 × 1
Backup Battery LifeAbout 5 years or more at 25oC but subjects to the temperature and the conditions during usage.
Operation Temperature0 o C ~ 40 o C
Storage Temperature-20 oC ~ +60 oC, 10% ~ 90% RH
Operating Environment10% ~ 90% RH【0 ~ 40 oC】; 10% ~ 55% RH【41 ~ 50 oC】; Pollution Degree 2
ViberationConforms to IEC61131-2; Continuous: 5Hz ~ 8.3Hz 3.5 mm, 8.3Hz ~ 150Hz 1G
ShockConforms to IEC60068-2-27; 11ms, 15G Peak , X, Y, Z direction for 6 times
Dimensions (W) x (H) x (D) mm257.4 × 170.3 × 71.8 (Emergency stop switch and hook are included.)
Weight750 g (cable excluded)
Obtain a Quote for Delta 3-Position Operation Switch HMI, DOP-H07S425 at economical prices. Specifications Overview for DOP-H07S425 reveals LED Back Light, 7" Widescreen TFT LCD, 65536 colors, 800 x 480 450 20000 20000 400 MHz 128 MB. It also includes 64 MB, 16 MB, Multi-Tone Frequency(2K ~ 4K Hz)/ 80dB N/A 1 USB Client Ver 2.0 SD card (supports SDHC) RS-422 / RS-485(Note 2 Built-in Natural cooling CE IP55. Take the First Step with a Quote for your requirement of Delta 3-Position Operation Switch HMI. Our commitment to better pricing and exceptional support sets us apart from other Competitors.