+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

EPP3744-0041 - Beckhoff Industrial Housing

Technical Specifications of Beckhoff Industrial Housing EPP3744-0041:

BrandBeckhoff
Product TypeIndustrial Housing
ProductEPP3744-0041

EPP3744-0041 Beckhoff Industrial Housing Technical Specifications

SpecificationValue
ProtocolEtherCAT
Bus interface2 x M8 socket, P-coded, shielded
SpecificationEN 61131-2, type 1/3
Number of inputs4 x pressure, 6 x digital
Input filter10 µs (for digital inputs)
Sensor supplyfrom load supply voltage, max. 0.5 A, short-circuit proof in total
Current consumption from UStyp. 100 mA
Operating temperature-25...+60°C
Storage temperature-40...+85°C
Vibration/shock resistanceconforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emissionconforms to EN 61000-6-2/EN 61000-6-4
Protect. rating/installation pos.IP65/66/67 (conforms to EN 60529)/variable
Approvals/markingsCE, UL
Housing - Dimensions (W x H x D)30 mm x 126 mm x 26.5 mm
Housing - MaterialPA6 (polyamide)
Housing - Installation2 fixing holes 3.5 mm diameter for M3
Special featuresdirect pressure measuring at the machine
Electrical isolation500 V
Load typeohmic, inductive, lamp load
Max. output current0.5 A per channel, individually short-circuit proof
Short-circuit currenttyp. 1.5 A
Number of outputs2 x digital
Conversion time~ 3.5 ms
Resolution1 mbar per digit
Signal typeair pressure
Measurement error/uncertainty3%
Nominal voltage24 V DC (-15%/+20%)
Connection methoddigital signals: 4-pin M8; pressure measurement: 6 mm fitting