Omron E2B-S08LN04-WP-C2 2M Proximity Sensor
Omron E2B-S08LN04-WP-C2 2M uses an M8 unshielded inductive sensing arrangement with a 4 mm sensing distance, 0 to 3.2 mm setting range, and long-body format. Its DC 3-wire NPN NC output is wired through a pre-wired 2 m cable and operates from a 10 to 30 VDC supply. Response frequency is 1,000 Hz, with control output specified at 200 mA max. at 32 VDC max. and voltage drop limited to 2 V. A yellow operation indicator is included together with reverse-polarity, surge, and short-circuit safeguards. Find the E2B Proximity Sensor Series within NPN proximity sensors offered by Omron Automation.

| Brand | Omron |
| Product | Proximity Sensors |
| Model Number | E2B-S08LN04-WP-C2 2M |
Omron E2B-S08LN04-WP-C2 2M Proximity Sensor - Technical Specifications
| Specification | Value |
|---|---|
| Sensor | Inductive |
| Housing Shape | Cylindrical |
| Size | M8 |
| Mounting type | Unshielded |
| Sensing Distance | 4 mm |
| Setting Distance | 0 to 3.2 mm |
| Output configuration | DC, 3-wire, NPN |
| Operation Mode | NC |
| Body Length | Long body |
| Connection Method | Pre-wired 2M Cable |
| Detectable Object | Ferrous metal |
| Standard Sensing Object | 12 × 12 × 1 mm |
| Response Frequency | 1,000 Hz |
| Power Supply Voltage | 10 to 30 VDC. |
| Protection Circuit | Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection |
| Ambient Temperature Range | Operation and storage : -25 to 70ºC |
| Degree of Protection | (1) IP67 (IEC60529) (2) EMC (EN60947-5-2) |
| Control Output | 200 mA max. (32 VDC max.), 2 V max. |
| Indicators | Operation indicator (Yellow LED) |
| Materials | Stainless steel, PBT, Standard cable is 4 mm dia. PVC. Brass-nickel plated, Zinc-plated iron |
| Weight | Approx. 65 g |
The Omron E2B-S08LN04-WP-C2 2M Proximity Sensor has an M8 cylindrical unshielded sensing body with a 4 mm sensing distance, 0 to 3.2 mm setting range, and long-body construction. DC 3-wire NPN NC output is provided through a pre-wired 2 m cable, with operating voltage from 10 to 30 VDC. Ferrous metal is the specified sensing object, and the standard object measures 12 × 12 × 1 mm. Response frequency is rated at 1,000 Hz. Control output supports 200 mA max. at 32 VDC max. with a maximum 2 V voltage drop, while a yellow LED indicates operation. Reverse-polarity, surge, and short-circuit protection are also included.
Environmental specifications cover -25 to 70°C for both operation and storage, together with IP67 under IEC 60529 and EMC under EN60947-5-2. Stainless steel, PBT, brass-nickel-plated material, zinc-plated iron, and PVC cable construction are listed. In long-body M8 installations requiring NPN NC switching, the E2B-S08LN04-WP-C2 provides direct cable wiring and the specified 4 mm sensing distance. For a similar M8 E2B model with a 2 mm sensing distance and PNP NC output, see E2B-S08LN02-WP-B2 2M.