Omron S8FS-G01515CD Power Supply

Omron S8FS-G01515CD SMPS is a 15 W switch mode power supply designed to provide 15 VDC with a rated output current of 1 A. It operates from 100 to 240 VAC input at 50/60 Hz and uses DIN rail mounting, screw terminals, and terminal blocks for structured panel installation. Efficiency is specified at 84% typical across 100 VAC, 200 VAC, and 230 VAC input conditions. Within the S8FS-G Series, the S8FS-G01515CD provides a DIN rail 15 W, 15 VDC configuration. Compare other DIN rail SMPS models from Omron automation.

Omron S8FS-G01515CD Power Supply
BrandOmron
ProductPower Supply
Model NumberS8FS-G01515CD

Omron S8FS-G01515CD Power Supply - Technical Specifications

SpecificationValue
Power rating15 W
Output voltage15 VDC
Rated output current1 A
Terminal typeScrew Terminal
Mounting methodDIN rail
ConnectionTerminal blocks
Efficiency84 % typ.(at 100 VAC input) 84 % typ.(at 200 VAC input) 84 % typ.(at 230 VAC input)
Rated input voltage100 to 240 VAC
Rated input current0.32 A typ.(at 100 VAC input) 0.2 A typ.(at 200 VAC input)
Input Leakage current0.5 mA max.(at 100 VAC input) 1 mA max.(at 200 VAC input)
Input Frequency50/60 Hz
Output indicatorYes (color: green)
Output voltage variable range-10 to +15 % (With V.ADJ)
Start-up time1000 ms max.(at 100 VAC input) 1000 ms max.(at 200 VAC input)
Hold time15 ms typ.(at 100 VAC input) 75 ms typ.(at 200 VAC input)
Vibration resistance10 to 55 Hz, 4.5 G max., 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance150 m/s2, in each 6 directions 3 times
Ambient temperature (Operating)-20 to 70 ?
Ambient temperature (Storage)-25 to 75 ?
Ambient humidity (OperatingStorage)90 %RH max.
Cooling fanNo
Weight250 g max.

The Omron S8FS-G01515CD Power Supply provides 15 W rated power with a 15 VDC output and 1 A rated current. It operates from 100 to 240 VAC input at 50/60 Hz and uses DIN rail mounting, screw terminals, and terminal blocks for organized panel installation. Efficiency is 84% typical at 100 VAC, 200 VAC, and 230 VAC input. A green output indicator provides status visibility, while V.ADJ allows -10% to +15% adjustment around nominal voltage. Startup time is 1000 ms maximum at both 100 VAC and 200 VAC, while hold time is 15 ms typical at 100 VAC and 75 ms typical at 200 VAC. The fanless unit operates from -20 to 70°C and weighs up to 250 g. These specifications define the DIN rail version of the 15 VDC, 15 W configuration.

The connected equipment should require 15 VDC and remain within the 1 A rated current. DIN rail space, terminal access, and source voltage should be confirmed during panel planning. Since the electrical output is the same as the direct-mount version, installation method becomes the primary difference between the two configurations. For the same 15 W power rating, 15 VDC output, and 1 A current with direct mounting, compare the Omron S8FS-G01515C.