Omron S8FS-G01512CD Power Supply

Omron S8FS-G01512CD SMPS is a compact 15 W switch mode power supply designed to provide 12 VDC with 1.3 A rated output current. It accepts 100 to 240 VAC input at 50/60 Hz and uses DIN rail mounting, screw terminals, and terminal blocks for organized panel installation. Efficiency is specified at 84% typical with 100 VAC, 200 VAC, and 230 VAC input. Within the S8FS-G Series, the S8FS-G01512CD provides a DIN rail 15 W, 12 VDC configuration. Compare other 15W 12V power supplies from Omron automation solutions.

Omron S8FS-G01512CD Power Supply
BrandOmron
ProductPower Supply
Model NumberS8FS-G01512CD

Omron S8FS-G01512CD Power Supply - Technical Specifications

SpecificationValue
Power rating15 W
Output voltage12 VDC
Rated output current1.3 A
Terminal typeScrew Terminal
Mounting methodDIN rail
ConnectionTerminal blocks
Efficiency84 % typ.(at 100 VAC input) 84 % typ.(at 200 VAC input) 84 % typ.(at 230 VAC input)
Rated input voltage100 to 240 VAC
Rated input current0.32 A typ.(at 100 VAC input) 0.2 A typ.(at 200 VAC input)
Input Leakage current0.5 mA max.(at 100 VAC input) 1 mA max.(at 200 VAC input)
Input Frequency50/60 Hz
Output indicatorYes (color: green)
Output voltage variable range-10 to +15 % (With V.ADJ)
Start-up time1000 ms max.(at 100 VAC input) 1000 ms max.(at 200 VAC input)
Hold time14 ms typ.(at 100 VAC input) 70 ms typ.(at 200 VAC input)
Vibration resistance10 to 55 Hz, 4.5 G max., 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance150 m/s2, in each 6 directions 3 times
Ambient temperature (Operating)-20 to 70 ?
Ambient temperature (Storage)-25 to 75 ?
Ambient humidity (OperatingStorage)90 %RH max.
Cooling fanNo
Weight250 g max.

The Omron S8FS-G01512CD Power Supply provides 15 W rated power with a 12 VDC output and 1.3 A rated current. It accepts 100 to 240 VAC input at 50/60 Hz and uses DIN rail mounting, screw terminals, and terminal blocks for structured control-panel installation. Efficiency is specified at 84% typical across 100 VAC, 200 VAC, and 230 VAC input. A green output indicator provides operating status, while V.ADJ supports adjustment from -10% to +15%. Startup time is 1000 ms maximum at 100 VAC and 200 VAC, while hold time is 14 ms typical at 100 VAC and 70 ms typical at 200 VAC. The fanless model operates from -20 to 70°C and weighs up to 250 g. These specifications define a compact DIN rail 12 VDC supply.

The connected load should require 12 VDC and keep current demand within the 1.3 A rating. DIN rail availability, screw-terminal access, and incoming AC supply should be evaluated independently from output capacity. With voltage, wattage, and current held constant, mounting method becomes the primary distinction between configurations. For a direct-mount version providing the same 15 W, 12 VDC, and 1.3 A output, compare the Omron S8FS-G01512C.