+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

Omron WLSD3-LD-N Limit Switch

Omron WLSD3-LD-N uses a horizontal-ball plunger with screw terminals and a G½ conduit connection. Maximum pretravel is 2.8 mm, while an LED provides operation indication. The source specifies a 5 VDC, 1 mA resistive minimum load and an indicator range from 10 to 115 VAC/DC. IP67 protection, 100 MΩ minimum insulation resistance, and 25 mΩ maximum initial contact resistance are listed. The WLSD3-LD-N belongs to the WL Series within the horizontal ball plunger switch range from Omron switching products. The ball plunger and LED differentiate it from the WLSD-N.

Omron WLSD3-LD-N Limit Switch
BrandOmron
ProductLimit Switch
Model NumberWLSD3-LD-N

Omron WLSD3-LD-N Limit Switch – Technical Specifications

SpecificationValue
Terminal ShapeScrew terminals (Conduit size: G½)
Pretravel Pt2.8 mm max.
Minimum Applicable Load5 VDC 1 mA, resistive load, P level
Rated Voltage10 to 115 VAC/DC
Leakage Current Reference ValueApprox. 0.4 mA at 10 VAC/DC Approx. 0.5 mA at 115 VAC/DC
IndicatorLED (With operation indicator)
Ambient Temperature-10 to +80°C (with no icing)
Ambient Humidity35 to 95%RH
Shock ResistanceDestruction: 1,000 m/s2 min. Malfunction: 300 m/s2 min.
Degree Of ProtectionIP67
Insulation Resistance100 MΩ min. (at 500 VDC)
ActuatorHorizontal-ball plunger
Vibration ResistanceMalfunction: 10 to 55 Hz, 1.5-mm double amplitude
Contact Resistance25 mΩ max. (initial value for the built-in switch)
Rated Frequency50/60 Hz

The Omron WLSD3-LD-N Limit Switch combines a horizontal-ball plunger with screw terminals and a G½ conduit entry. Pretravel is specified at 2.8 mm maximum. An LED operation indicator is included, and the minimum applicable resistive load is 5 VDC at 1 mA. The indicator is specified for 10 to 115 VAC/DC, with approximate current of 0.4 mA at 10 VAC/DC and 0.5 mA at 115 VAC/DC. IP67 protection, 100 MΩ minimum insulation resistance at 500 VDC, and 25 mΩ maximum initial contact resistance are listed.

The switch operates from -10 to 80°C with 35 to 95% relative humidity. Malfunction vibration resistance covers 10 to 55 Hz at 1.5 mm double amplitude, while shock resistance is listed at 1,000 m/s² minimum for destruction and 300 m/s² minimum for malfunction. The ball-plunger actuator and LED distinguish this configuration from the standard horizontal-plunger version. For the corresponding no-indicator horizontal plunger model, see the WLSD-N.