Omron D4F-420-5D Limit Switch

Omron D4F-420-5D is a slow-action limit switch with a metal roller lever, resin roller, and 4NC contact configuration. The vertical actuator is paired with a 5 m cable and supports operating speeds from 1 mm/s to 0.5 m/s. IP67 protection, a minimum 2 × 2 mm contact gap, and 100 MΩ minimum insulation resistance are specified. The D4F-420-5D belongs to the D4F Series within the 4NC roller lever limit switch range from Omron limit switch products. Its four normally closed contacts and 5 m cable are the main selection points.

Omron D4F-420-5D Limit Switch
BrandOmron
ProductLimit Switch
Model NumberD4F-420-5D

Omron D4F-420-5D Limit Switch – Technical Specifications

SpecificationValue
Contact Form4NC
Shock ResistanceDestruction 1,000 m/s2 min. Malfunction 300 m/s2 min.
Degree Of ProtectionIP67
Insulation Resistance100 MΩ min.
Cable Length5 m
Pull Outing Direction Of CableVertical
Contact Gap2 × 2 mm min.
ActuatorRoller lever (Metal lever, resin roller)
Vibration ResistanceMalfunction 10 to 55 Hz, 0.75 mm single amplitude
Operating MechanismSlow-action
Operating Speed1 mm/s to 0.5 m/s
Operating FrequencyMechanical 120 operations/minute; Electrical 30 operations/minute
Contact Resistance300 mΩ max. (with 1 m cable), 500 mΩ max. (with 3 m cable), 700 mΩ max. (with 5 m cable)
Rated Insulation Voltage Ui250 V
Rated Frequency50/60 Hz
Ambient Operating Temperature−30 to 70°C (with no icing)
Ambient Operating Humidity95% max

The Omron D4F-420-5D Limit Switch uses a metal lever with a resin roller and four normally closed contacts operated through a slow-action mechanism. The actuator is vertically oriented and connected by a 5 m cable, giving this version extended wiring reach together with a roller-lever operating format. Movement speed is specified from 1 mm/s to 0.5 m/s, while mechanical operation is permitted up to 120 operations per minute and electrical operation up to 30 operations per minute. A minimum contact gap of 2 × 2 mm is listed together with IP67 protection and 100 MΩ minimum insulation resistance.

The 5 m cable corresponds to a maximum contact resistance of 700 mΩ. Operating temperature ranges from -30 to 70°C with relative humidity up to 95%. Malfunction vibration resistance covers 10 to 55 Hz at 0.75 mm single amplitude, while shock resistance is at least 1,000 m/s² for destruction and 300 m/s² for malfunction. The 4NC contact form is the strongest electrical distinction within this group. For a D4F roller-lever model using 2NC/2NO contacts instead, see the D4F-320-3D model.