+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

Omron D4F-302-3D Limit Switch

Omron D4F-302-3D is a vertical roller-plunger limit switch using a metal roller and 2NC/2NO slow-action contacts. A 3 m cable places this model between the shorter 1 m and longer 5 m versions while retaining the same actuator and contact configuration. IP67 protection, a 2 × 2 mm minimum contact gap, and operation from 1 mm/s to 0.5 m/s are specified. The D4F-302-3D belongs to the D4F Series within the multi-contact roller plunger switch range from Omron limit switch products. Cable length is the main selection difference for this version.

Omron D4F-302-3D Limit Switch
BrandOmron
ProductLimit Switch
Model NumberD4F-302-3D

Omron D4F-302-3D Limit Switch – Technical Specifications

SpecificationValue
Contact Form2NC/2NO
Shock ResistanceDestruction 1,000 m/s2 min. Malfunction 300 m/s2 min.
Degree Of ProtectionIP67
Insulation Resistance100 MΩ min.
Cable Length3 m
Pull Outing Direction Of CableVertical
Contact Gap2 × 2 mm min.
ActuatorRoller plunger (Metal roller)
Vibration ResistanceMalfunction 10 to 55 Hz, 0.75 mm single amplitude
Operating MechanismSlow-action
Operating Speed1 mm/s to 0.5 m/s
Operating FrequencyMechanical 120 operations/minute; Electrical 30 operations/minute
Contact Resistance300 mΩ max. (with 1 m cable), 500 mΩ max. (with 3 m cable), 700 mΩ max. (with 5 m cable)
Rated Insulation Voltage Ui250 V
Rated Frequency50/60 Hz
Ambient Operating Temperature−30 to 70°C (with no icing)
Ambient Operating Humidity95% max

The Omron D4F-302-3D Limit Switch keeps the metal roller plunger and 2NC/2NO contact structure of the D4F-302 family but uses a 3 m cable. Its actuator is vertically oriented, with slow-action operation across a speed range from 1 mm/s to 0.5 m/s. Mechanical switching frequency is specified at up to 120 operations per minute, with electrical switching at up to 30 operations per minute. A minimum 2 × 2 mm contact gap, IP67 protection, and 100 MΩ minimum insulation resistance are listed.

Maximum contact resistance for the 3 m cable is 500 mΩ. The switch withstands destructive shock of at least 1,000 m/s² and malfunction shock of at least 300 m/s². Malfunction vibration resistance covers 10 to 55 Hz at 0.75 mm single amplitude. Operating temperature extends from -30 to 70°C with humidity up to 95%. Since actuator type and contact form are shared with the 1D and 5D models, the 3 m lead is the most useful identifying difference. For the longer 5 m version, see the D4F-302-5D model.