Omron D4F-120-1R Limit Switch

Omron D4F-120-1R is a horizontal-orientation roller lever switch with a metal lever, resin roller, and 1NC/1NO slow-action contacts. A 1 m cable is provided, and the actuator supports operating speeds from 1 mm/s to 0.5 m/s. The switch carries IP67 protection, 100 MΩ minimum insulation resistance, and a minimum 2 × 2 mm contact gap. The D4F-120-1R sits within the D4F Series and the horizontal roller lever switch range from Omron control components. Horizontal actuator orientation is the key difference from D4F-120-1D.

Omron D4F-120-1R Limit Switch
BrandOmron
ProductLimit Switch
Model NumberD4F-120-1R

Omron D4F-120-1R Limit Switch – Technical Specifications

SpecificationValue
Contact Form1NC/1NO
Shock ResistanceDestruction 1,000 m/s2 min. Malfunction 300 m/s2 min.
Degree Of ProtectionIP67
Insulation Resistance100 MΩ min.
Cable Length1 m
Pull Outing Direction Of CableHorizontal
Contact Gap2 × 2 mm min.
ActuatorRoller lever (Metal lever, resin roller)
Vibration ResistanceMalfunction 10 to 55 Hz, 0.75 mm single amplitude
Operating MechanismSlow-action
Operating Speed1 mm/s to 0.5 m/s
Operating FrequencyMechanical 120 operations/minute; Electrical 30 operations/minute
Contact Resistance300 mΩ max. (with 1 m cable), 500 mΩ max. (with 3 m cable), 700 mΩ max. (with 5 m cable)
Rated Insulation Voltage Ui250 V
Rated Frequency50/60 Hz
Ambient Operating Temperature−30 to 70°C (with no icing)
Ambient Operating Humidity95% max
WeightApprox. 220 g

The Omron D4F-120-1R Limit Switch retains the metal-lever and resin-roller actuator used by the D4F-120 family but changes the operating orientation to horizontal. It uses slow-action 1NC/1NO contacts and a 1 m cable, with an operating-speed range from 1 mm/s to 0.5 m/s. Mechanical operating frequency is specified at 120 operations per minute and electrical frequency at 30 operations per minute. The minimum contact gap is 2 × 2 mm. IP67 protection, 100 MΩ minimum insulation resistance, and operation from -30 to 70°C are listed.

With the 1 m cable, contact resistance is specified at 300 mΩ maximum. Malfunction vibration resistance covers 10 to 55 Hz at 0.75 mm single amplitude. The switch withstands destructive shock of at least 1,000 m/s² and malfunction shock of at least 300 m/s². Because the actuator, contacts, and cable length closely match the vertical version, orientation becomes the primary model-selection difference. For the corresponding vertically oriented 1 m roller-lever version, see the D4F-120-1D model.