+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

Omron D4C-4302 Limit Switch

Omron D4C-4302 is a microload limit switch with a 12 mm × 4.4 mm sintered stainless steel roller plunger and SPDT switching. The rolling actuator suits moving parts that pass across the sensing point, while electrical ratings of 0.1 A at 125 VAC and 0.1 A at 30 VDC support low-current control circuits. A 5 m four-core VCTF oil-resistant cable provides extended prewired connection, and IP67 protection covers the switch body. The D4C-4302 belongs to the D4C Series within the microload roller plunger switch range from Omron limit switch products.

Omron D4C-4302 Limit Switch
BrandOmron
ProductLimit Switch
Model NumberD4C-4302

Omron D4C-4302 Limit Switch – Technical Specifications

SpecificationValue
Shape StructureGeneral-purpose Limit switches
CtuatorRoller plunger 12 dia. x 4.4 Sintered stainless steel roller
Contact FormSPDT
Electrical Ratings0.1 A at 125 VAC/ 0.1 A at 30 VDC
LoadMicro load
Ambient TemperatureOperating: -10 to 70 ℃ (with no icing)
Ambient Humidity35 to 95% RH
Shock ResistanceDestruction: 1,000 m/s 2 max. Malfunction: 500 m/s 2 max.
Degree Of ProtectionIP67
Contact Resistance Initial Value400 mΩ max.
DurabilityElectrical: 200,000 operations min. (5 A at 125 VAC) Mechanical: 10 million operations min.
Cable SpecificationsVCTF oil-resistant cable, 4 cores, 5 m Nominal sectional area: 0.75 mm 2 Diameter: 7.6 dia.

The Omron D4C-4302 Limit Switch uses a 12 mm × 4.4 mm sintered stainless steel roller plunger with SPDT switching for microload position detection. Electrical ratings are 0.1 A at 125 VAC and 0.1 A at 30 VDC. A four-core 5 m VCTF oil-resistant cable is supplied, with a nominal conductor sectional area of 0.75 mm² and a cable diameter of 7.6 mm. IP67 protection covers the switch body, while operation is specified from -10 to 70°C with 35 to 95% relative humidity.

Mechanical durability is specified at 10 million operations minimum, while the source also lists electrical durability at 200,000 operations minimum at 5 A, 125 VAC. Initial contact resistance is 400 mΩ maximum. Destructive shock resistance reaches 1,000 m/s² maximum and malfunction shock resistance reaches 500 m/s² maximum. The roller plunger provides smooth contact where a target passes across the sensing point, while the 5 m cable gives extended routing distance. For a related microload D4C roller-plunger model using a shorter 3 m cable, see the D4C-4203 model.