Omron G3FM-2R5SLN DC24 Solid-state Relay
Omron G3FM-2R5SLN DC24 is a solid state relay with photo volt coupler isolation, socket mounting, a plug-in terminal structure, and an equipped operating indicator. The model has a 24 VDC rated voltage and supports rated load voltages of 24 to 110 VDC and 24 to 240 VAC. Load current is specified as 1 to 500 mA at 40°C, with an operate time of 5 ms max. and a release time of 10 ms max. Output ON voltage drop is 3 V max. RMS. The G3FM-2R5SLN DC24 belongs to the G3FM series within the Solid state relay portfolio from Omron relay components.

| Brand | Omron |
| Product | Solid State Relay |
| Model Number | G3FM-2R5SLN DC24 |
Omron G3FM-2R5SLN DC24 Solid-state Relay - Technical Specifications
| Specification | Value |
|---|---|
| Isolation Method | Photo volt coupler |
| Mounting | Socket |
| Operating Indicator | Equipped |
| Rated Voltage | 24 VDC |
| Rated Load Voltage | 24 to 110 VDC 24 to 240 VAC |
| Terminal Structure | Plug-in terminal |
| Load Current | 1 to 500 mA (at 40 ℃) |
| Operate Time | 5 ms max. |
| Release Time | 10 ms max. |
| Output On Voltage Drop | 3 V max. (RMS) |
| Leakage Current | 0.1 mA max. (at 200 VAC) |
| Insulation Resistance | 100 MΩ min. (at 500 VDC) |
| Dielectric Strength | 1500 VAC 50/60 Hz 1 min |
| Vibration Resistance | 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) |
| Shock Resistance | 1000 m/s2 |
| Ambient Temperature Operating | -30 to 80 ℃ (with no freezing or condensation) |
| Ambient Temperature Storage | -30 to 100 ℃ (with no freezing or condensation) |
| Ambient Humidity Operating | 45 to 85 % |
| Weight | Approx. 50 g |
The Omron G3FM-2R5SLN DC24 Solid State Relay uses photo volt coupler isolation with socket mounting, plug-in terminals, and an equipped operating indicator. Its rated input voltage is 24 VDC. The supplied output specification covers both 24 to 110 VDC and 24 to 240 VAC, while the output load-current range is 1 to 500 mA at 40°C. These values distinguish the G3FM-2R5SLN DC24 from the surrounding G3F and G3FD models, which use different output voltage and current ranges. The available source data does not list the same zero-cross, input operating-range, input operate-voltage, or input release-voltage fields shown for several adjacent models, so those details are not added here.
Operate time is specified as 5 ms max. and release time as 10 ms max. Output ON voltage drop is 3 V max. RMS, while leakage current is 0.1 mA max. at 200 VAC. Insulation resistance is 100 MΩ min. at 500 VDC and dielectric strength is 1500 VAC at 50/60 Hz for 1 minute. Vibration resistance is specified from 10 to 55 to 10 Hz at 0.75 mm single amplitude or 1.5 mm double amplitude, together with shock resistance of 1000 m/s². Operating temperature ranges from -30 to 80°C without freezing or condensation, storage extends from -30 to 100°C, and humidity is 45 to 85%. For another model grouped under the supplied G3F relay pages, see G3F-203SN-VD DC5-24.


