The Omron H7CC-R11 Counter is a precise tachometer for speed and frequency monitoring, equipped with SPDT contact output and high-speed 10 kHz counting capability. Its 6-digit LCD ensures excellent visibility, while UP/DOWN input modes provide flexible integration with various sensors. The device features strong environmental durability with −10 to 55°C operation and IP66 panel protection when paired with waterproof packing. Designed for dependable industrial use, it includes non-volatile memory for long-term data retention. Manufactured by Omron and supplied under Omron Counter offerings, it is part of the Omron H7CC Series.
No-voltage Input Impedance when ON: 1 kΩ max. (Leakage current: 12 mA when 0 Ω) ON residual voltage: 3 V max. Impedance when OFF: 100 kΩ min. Voltage Input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
Counter One-shot output time
0.001 to 99.999 (in Tachometer Mode)/ 0.0 to 99.9 s
Input signal
Count and hold
Prescaling function
0.001 to 99.999 (in Tachometer Mode)
Classification
Tachometer
Configuration
Tachometer
Power supply voltage
100 to 240 VAC
Mounting method
Flush mounting or surface mounting
External connections
11-pin socket
Outputs
Contact output (SPDT)
Digits
6 digits (0 to 999999)
Operating voltage fluctuation range
85% to 110% of rated supply voltage (12 to 48 VDC: 90% to 110%)
Sensor waiting time
290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Counter Reset system
290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Tachometer
Rightmost 3 digits
Control output
Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1) Minimum applied load:10 mA at 5 VDC (failure level: P, reference value)
Display
7-segment, negative transmissive LCD Character height Present value: 10 mm (white), comparison value: 6 mm (green)
Memory backup
Non-volatile memory (overwrites: 100,000 times min.) that can store data for 10 years min
Storage temperature range
−10 to 55°C (−10 to 50°C if Counter/Tachometers are mounted side by side) (with no icing or condensation)
Operating humidity range
25% to 85%
Input mode
No-voltage (NPN) input/voltage (PNP) input (switchable)
No-voltage inputs:
ON impedance: 1 kΩ max. (Leakage current: 12 mA at 0 Ω) ON residual voltage: 3 V max.
OFF impedance: 100 kΩ min.
Voltage input:
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
Degree of protection
IEC IP66 for panel surface only and only when Y92S-P6 Waterproof Packing is used