Maintenance teams planning replacements for USP-PI-PARALLEL-INTERFACE frequently review Schmersal Limit Switch, Schmersal Usp 100 M24Bs and Schmersal Door Locking Devices to prevent downtime, checking availability and compatibility with existing systems.
Schmersal USP-PI PARALLEL-INTERFACE Elevator Positioning System
The Schmersal USP-PI PARALLEL-INTERFACE Elevator Positioning System (Item No: 101159354) offers a PVC housing material, IP00 degree of protection, 24 VDC rated operating voltage, 150 mA operating current. Manufactured by Schmersal under the Schmersal Elevator Positioning System. category, this model belongs to the Schmersal USP Series.
| Brand | Schmersal |
| Product Type | Elevator positioning system |
| Model Number | USP-PI PARALLEL-INTERFACE |
Schmersal USP-PI PARALLEL-INTERFACE Elevator Positioning System – Technical Specifications
| Specification | Value |
|---|---|
| Housing material | PVC |
| Gross weight | 215 g |
| Mounting | Snaps onto standard DIN rails according to DIN EN 50022 and EN 50035 |
| Termination | Screw terminals M20 x 1.5 |
| Cable section, minimum | 0.5 mm² |
| Cable section, maximum | 1.5 mm² |
| Width | 160 mm |
| Height | 89.6 mm |
| Degree of protection | IP00 |
| Ambient temperature | -5 ... +60 °C |
| Storage and transport temperature | -25 ... +70 °C |
| Resistance to vibrations | 10 … 55 Hz / 0.0375 mm |
| Restistance to shock | 15 g / 11 ms |
| Overvoltage category | III |
| Degree of pollution | 2 |
| Operating voltage | 24 VDC -10 % / +15 % |
| Rated operating voltage | 24 VDC |
| Operating current | 150 mA |
| Length of cable, maximum | 30 m |
| Input signal, HIGH Signal "1" | 10 … 30 VDC |
| Input signal, LOW Signal "0" | 0 … 2 VDC |
| Designation, Digital outputs | Y1 ... Y6 |
| Output current, maximum | 100 mA |
| Design of control elements | p-type |
Ask for the Pricing of Schmersal Elevator Positioning System USP-PI PARALLEL-INTERFACE Item No: 101159354 at unbeatable prices. Detailed Specifications of USP-PI PARALLEL-INTERFACE, 101159354 feature PVC housing designed for durability in elevator shaft environments. It operates on a supply with an input voltage tolerance of 24 VDC -10 % / +15 % ensuring stable performance under variable conditions. The rated operating voltage is 24 VDC, and it consumes just 150 mA of current, making it energy-efficient for continuous elevator operation. With a gross weight of 215 g, the USP system is lightweight yet robust. It carries an IP00 rating and is intended for installation in protected environments. The device functions reliably within an ambient temperature range of -5 ... +60 °C, making it suitable for a wide range of elevator applications. Now's the Time to Secure a Quote for your requirement of Elevator Positioning System USP-PI PARALLEL-INTERFACE. We're committed to offering more favorable pricing and more responsive support than other Traders.