DRP048V120W1BA - Delta 2.5A 48V DIN Rail Power Supply
Technical Specifications of Delta DRP048V120W1BA 2.5A 48V DIN Rail Power Supply

| Brand | Delta |
| Product Type | SMPS |
| Product | DRP048V120W1BA |
Delta 2.5A 48V DIN Rail Power Supply DRP048V120W1BA Technical Specifications:
| Specification | Value |
|---|---|
| Output Current | 2.5A |
| Output Voltage | 48V |
| Output Voltage Adjustment Range | 48-56Vdc |
| Output Power | 120W |
| Line Regulation | < 0.5% (@ 85-264Vac input, 100% load) |
| Load Regulation | < 1.0% (@ 85-264Vac input, 0-100% load) |
| PARD | < 200mVpp |
| Start-up Time | < 2,000ms @ nominal input (100% load) |
| Hold-up Time | > 20ms @ 115Vac, > 50ms @ 230Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 2% @ 85-264Vac input, 0-100% load (Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz) |
| Start-up with Capacitive Loads | 6,500μF Max |
| Rise Time | < 200ms @ nominal input (100% load) |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 85-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| DC Input Voltage Range | 120-375Vdc |
| Input Current | < 2.20A @ 115Vac, < 1.10A @ 230Vac |
| Efficiency at 100% load | > 90.0% @ 115Vac, > 91.0% @ 230Vac |
| Inrush Current | < 35A @ 115Vac & 230Vac |
| Power Factor at 100% load | > 0.99 @ 115Vac, > 0.93 @ 230Vac |
| Leakage Current | < 1mA @ 240Vac |
| Power Dissipation | 0% load: < 2.5W @ 115Vac, < 3.5W @ 230Vac 100% load: < 13.2W @ 115Vac, < 11.8W @ 230Vac |
| Case Chassis / Cover | Aluminium |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Input Terminal | 3 Pins (Rated 300V/15A) |
| Output Terminal | 4 Pins (Rated 300V/15A) |
| Noise Sound Pressure Level (SPL) | < 40dBA |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Wire | Input / Output: AWG 20-12 |
| Unit Weight | 0.72 kg (1.59 lb) |
| Operating Temperature | -25°C to +80°C (Cold Start at -40°C) |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | Vertical: > 50°C de-rate power by 2.5% / °C Horizontal: > 50°C de-rate power by 2.5% / °C, > 70°C de-rate power by 3.5% / °C |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC60068-2-27, 30G (300m/S²) for a duration of 18ms, 1 time per direction, 2 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, 10Hz to 500Hz @ 30m/S² (3G peak); 60 min per axis for all X, Y, Z direction |
| Operating Altitude | 0 to 2,500 Meters (8,200 ft.) |
| Pollution Degree | 2 |
| Bump Test (Operating) | IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total |
| Over Voltage Category | III According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part) |
Mail Us for your needs in Delta 2.5A 48V DIN Rail Power Supply DRP048V120W1BA with budget-friendly prices. The Main Technical Parameters of DRP048V120W1BA include 2.5A Output Current, 48V Output Voltage, 120W Output Power at competitive prices. It operates with a nominal input voltage of 100-240Vac and supports an input voltage range of 85-264Vac. The power supply covers a nominal input frequency of 50-60Hz, with a broader input frequency range of 47-63Hz. With an input current of < 2.20A @ 115Vac, < 1.10A @ 230Vac, it ensures efficient performance. The unit features a Green LED (DC OK) indicator, aiding in quick status checks. Both input and output terminals have 3 Pins (Rated 300V/15A) and 4 Pins (Rated 300V/15A) for secure connections. Designed for extreme environments, it Operating Temperature from -25°C to +80°C (Cold Start at -40°C) and has a storage temperature of -40°C to +85°C. Customize Your Experience with a Quote for your requirement of 2.5A 48V DIN Rail Power Supply. Experience the difference with our competitive pricing and superior support over other Suppliers.