DRM-24V960W3PN - Delta 24V 960W DIN Rail Power Supply
Technical Specifications of Delta DRM-24V960W3PN 24V 960W DIN Rail Power Supply

| Brand | Delta |
| Product Type | SMPS |
| Product | DRM-24V960W3PN |
Delta24V 960W DIN Rail Power Supply DRM-24V960W3PN Technical Specifications:
| Specification | Value |
|---|---|
| Output Current | 40A |
| Output Voltage | 24V |
| Output Voltage Adjustment Range | 24-28Vdc |
| Output Power | 960W |
| Line Regulation | 10mV (@ 3 x 320-575Vac input, 100% load) |
| Load Regulation | 80mV (@ 3 x 320-575Vac input, 0-100% load) |
| PARD | 100mVpp Max. |
| Start-up Time | 1,000ms @ 24V, 40A |
| Hold-up Time | 50.4ms @ 24V, 20A |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 5% @ 1.5-100% load |
| Start-up with Capacitive Loads | 40,000μF |
| Rise Time | 65ms |
| Power Boost Duration | 5 seconds Typ. 7 seconds Max. |
| Power Boost Recovery Time | 17 seconds Typ. |
| Nominal Input Voltage | 3 x 400-500Vac |
| Input Voltage Range | 3 x 320-575Vac (3-Phase) or 2 x 380-575Vac (2-Phase) |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Nominal DC Input Voltage | - |
| DC Input Voltage Range | 450-800Vdc |
| Input Current | 1.53A @ 24V, 40A |
| Efficiency at 100% load | 95.75% @ 24V, 40A |
| Inrush Current | 14.2A |
| Power Factor at 100% load | 0.95 @ 24V, 40A |
| Leakage Current | < 0.62mA / 0.64mA @ 3 x400Vac, 50Hz, TN/TT / IT system |
| Power Dissipation | - |
| Case Chassis / Cover | Aluminium |
| Indicator | Green LED DC OK Red LED Overload |
| Cooling System | Convection |
| Input Terminal | 4 Pins (Rated 600V/35A) |
| Output Terminal | 4 Pins (Rated 300V/65A) |
| Noise Sound Pressure Level (SPL) | < 25dBA |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Wire | - |
| Unit Weight | 2.3kg (5.07 lb) |
| Operating Temperature | -25°C to +70°C (Cold start -40°C) |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | Vertical Mounting: 3-Phase : > 60°C de-rate power by 2.5% / °C 2-Phase: > 50°C de-rate power by 2.5% / °C Horizontal Mounting : 3-Phase: > 40°C de-rate power by 1.67% / °C 2-Phase: > 40°C de-rate power by 2% / °C |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 30G for a duration of 18ms; 3 times per direction, 6 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions |
| Operating Altitude | OVC III : 0 to 2,500 Meters (8,200 ft.) OVC II : 2,500 to 6,000 Meters (19,680 ft.), 0 to 5,000 Meters (16,400 ft.), 0 to 3,000 Meters (9,840 ft.) |
| Pollution Degree | 2 |
| Bump Test (Operating) | IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total |
| Over Voltage Category | - |
| Signal Terminal | 5 Pins (Rated 300V/12A) |
Call us for Delta 24V 960W DIN Rail Power Supply DRM-24V960W3PN at the best rates. Technical Attributes of DRM-24V960W3PN are 40A Output Current, 24V Output Voltage, 960W Output Power at competitive prices. It operates with a nominal input voltage of 3 x 400-500Vac and supports an input voltage range of 3 x 320-575Vac (3-Phase) or 2 x 380-575Vac (2-Phase). The power supply covers a nominal input frequency of 50-60Hz, with a broader input frequency range of 47-63Hz. With an input current of 1.53A @ 24V, 40A, it ensures efficient performance. The unit features a Green LED DC OK Red LED Overload indicator, aiding in quick status checks. Both input and output terminals have 4 Pins (Rated 600V/35A) and 4 Pins (Rated 300V/65A) for secure connections. Designed for extreme environments, it Operating Temperature from -25°C to +70°C (Cold start -40°C) and has a storage temperature of -40°C to +85°C. Unlock Exclusive Pricing with a Quote for your requirement of 24V 960W DIN Rail Power Supply. Trust in our ability to provide more advantageous pricing and dedicated support beyond other other Dealers.