Many procurement teams check ELECTRIC-LC1E50N5 against Schneider VFD, Schneider Electric Lc1E1810M7 and Schneider Contactors Easy Tesys before signing purchase orders, verifying quality, compliance, and after-sales support availability.
Schneider LC1E50N5 Contactor
Technical Specifications of Schneider 50A Easy TeSys 415V AC 3P Contactor LC1E50N5:

| Product Component Type | Contactor |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
| Power Dissipation Per Pole | 3.8 W AC-37.4 W AC-1 |
| Tightening Torque | Control circuit: 1.2 N.mPower circuit: 5 N.m |
Schneider LC1E50N5 Contactor – Technical Specifications
| Specification | Value |
|---|---|
| Range | Easy TeSys |
| Range of product | Easy TeSys Control |
| Product or component type | Contactor |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
| [Ie] rated operational current | 50 A (at <55 °C) at <= 440 V AC AC-3 for power circuit70 A (at <55 °C) at <= 440 V AC AC-1 for power circuit |
| [Uc] control circuit voltage | 415 V AC 50 Hz |
| Motor power kW | 15 kW at 220...230 V AC 50/60 Hz (AC-3)22 kW at 380...400 V AC 50/60 Hz (AC-3)25 kW at 415 V AC 50/60 Hz (AC-3)30 kW at 440 V AC 50/60 Hz (AC-3)30 kW at 500 V AC 50/60 Hz (AC-3)33 kW at 660...690 V AC 50/60 Hz (AC-3) |
| Pole contact composition | 3 NO |
| [Ith] conventional free air thermal current | 70 A (at 55 °C) |
| Irms rated making capacity | 500 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
| Rated breaking capacity | 400 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 400 A 40 °C - 10 s for power circuit208 A 40 °C - 60 s for power circuit84 A 40 °C - 600 s for power circuit |
| Associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1100 A gG at <= 690 V coordination type 1 for power circuit |
| Power dissipation per pole | 3.8 W AC-37.4 W AC-1 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
| [Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 |
| Control circuit type | AC at 50 Hz |
| Control circuit voltage limits | 0.85...1.1 Uc (-5…55 °C):operational 50 Hz0.3...0.6 Uc (-5…55 °C):drop-out 50 Hz |
| Inrush power in VA | 160 VA 50 Hz cos phi 0.75 (at 20 °C)140 VA 60 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 15 VA 50 Hz cos phi 0.3 (at 20 °C)13 VA 60 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 6…10 W for control circuit |
| Operating time | 20...26 ms on closing8...12 ms on opening |
| Maximum operating rate | 1200 cyc/h 60 °C |
| Connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: solid without cable end |
| Tightening torque | Control circuit: 1.2 N.mPower circuit: 5 N.m |
| Auxiliary contact composition | 1 NO + 1 NC |
| Minimum switching voltage | 17 V for control circuit |
| Minimum switching current | 5 mA for control circuit |
| Mounting support | PlateDIN rail |
| IP degree of protection | IP2X conforming to IEC 60529 |
| Height | 127 mm |
| Width | 75 mm |
| Depth | 114 mm |
| Net weight | 0.98 kg |
Give Us a Call for Schneider 50A Easy TeSys 415V AC 3P Contactor LC1E50N5 at the lowest pricing. In-depth Technical Analysis of LC1E50N5 feature Easy TeSys Control Range of products and the Contactor Product or component type 3P, designed for efficient performance in Power circuit: <= 690 V AC 50/60 Hz. This product features a rated operational current of 50 A (at <55 °C) at <= 440 V AC AC-3 for power circuit70 A (at <55 °C) at <= 440 V AC AC-1 for power circuit. It operates at a control circuit voltage of 415 V AC 50 Hz, with 3 NO poles. The conventional free air thermal current is rated at 70 A (at 55 °C), and power dissipation per pole is 3.8 W AC-37.4 W AC-1. The rated insulation voltage is 690 V conforming to IEC 60947-4-1, and the impulse withstand voltage is 6 kV coil not connected to the power circuit conforming to IEC 60947. Elevate Your Project with a Quote for your requirement of Schneider 50A Easy TeSys 415V AC 3P Contactor. Our promise: More affordable pricing and more personalized support than other Distributors & Dealers.