Schneider ATV610D18N4 Variable Speed Drive

The Schneider Altivar 610 18.5kW Variable Speed Drive ATV610D18N4 is a high-efficiency VFD built for modern industrial automation needs.

BrandSchneider
Product TypeVFD - Variable Frequency Drive
Model NumberATV610D18N4

Schneider ATV610D18N4 Variable Speed Drive – Technical Specifications

SpecificationValue
Mounting modeCabinet mount
Height495 mm580 mm with EMC plate
Analogue input typeAI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bitsAI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bitsAI2, AI3 software-configurable temperature probe or water level sensor
Relative humidity5…95 % without condensation conforming to IEC 60068-2-3
Range of productEasy Altivar 610
Ambient air temperature for operation-15…45 °C (without derating)45…60 °C (with derating factor)
Communication port protocolModbus serial
Operating positionVertical +/- 10 degree
Linearity errorAI1, AI2, AI3: +/- 0.15 % of maximum value for analog inputAQ1, AQ2: +/- 0.2 % for analog output
Product destinationAsynchronous motorsSynchronous motors
IP degree of protectionIP20
number of preset speeds16 preset speeds
Line current37.2 A at 380 V (normal duty)33.5 A at 460 V (normal duty)31.6 A at 380 V (heavy duty)28.3 A at 460 V (heavy duty)
Braking to standstillBy DC injection
Number of Units in Package 24
Analogue input number3
Output voltage<= power supply voltage
Analogue output typeSoftware-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bitsSoftware-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Refresh timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Sampling duration5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input2 ms +/- 0.5 ms (DI1...DI6)configurable - discrete input5 ms +/- 1 ms (DI5, DI6)configurable - pulse input10 ms +/- 1 ms (AQ1, AQ2) - analog output
Depth232 mm
Acceleration and deceleration rampsLinear adjustable separately from 0.01 to 9000 sS, U or customized
Product specific applicationFan, pump, compressor, conveyor
Continuous output current39.2 A at 4 kHz for normal duty31.7 A at 4 kHz for heavy duty
Apparent power26.7 kVA at 460 V (normal duty)22.6 kVA at 460 V (heavy duty)
Product or component typeVariable speed drive
Width211 mm
SupplyExternal supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protectionInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
Maximum transient current43.1 A during 60 s (normal duty)47.6 A during 60 s (heavy duty)
Physical interface2-wire RS 485 for Modbus serial
EMC filterIntegrated conforming to IEC 61800-3 category C3 with 50 m
Discrete input typeDI1...DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhmDI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
Accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Ambient air temperature for storage-40…70 °C
Noise level65 dB conforming to 86/188/EEC
Relay output number3
Discrete input logicPositive logic (source): DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)Negative logic (sink): DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
Connector type1 RJ45 (on the remote graphic terminal) for Modbus serial
Relay Output TypeConfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cyclesConfigurable relay logic R2: sequence relay NO electrical durability 100000 cyclesConfigurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Net Weight13.5 kg
Motor power hp25 hp for normal duty20 hp for heavy duty
Electrical connectionControl, screw terminals: 0.5...1.5 mm²Line side, screw terminal: 10...16 mm²Motor, screw terminal: 10...16 mm²
Transmission frameRTU for Modbus serial
Maximum switching currentRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V ACRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DCRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Pollution degree2 conforming to IEC 61800-5-1
Analogue output number2
Switching frequency2...12 kHz adjustable
Motor power kW18.5 kW for normal duty15 kW for heavy duty
Supply frequency50...60 Hz +/-5 %
Output frequency0.1…500 Hz
Protection typeThermal protection: motorMotor phase break: motorThermal protection: driveOverheating: driveOvercurrent between output phases and earth: driveOverload of output voltage: driveShort-circuit protection: driveMotor phase break: driveOvervoltages on the DC bus: driveLine supply overvoltage: driveLine supply undervoltage: driveLine supply phase loss: driveOverspeed: driveBreak on the control circuit: drive
Type of coolingForced convection

The Schneider ATV610D18N4 is a compact VFD from the Easy Altivar 610 range, engineered for 18.5kW (25HP) three-phase motor control in pumps, fans, compressors, and conveyors—delivering soft starts, precise speed/torque, and energy savings for industrial automation.

Built for dependable plant operation, the ATV610D18N4 provides 18.5kW (ND) / 15kW (HD) with continuous output currents of 39.2A (ND, 4kHz) and 31.7A (HD, 4kHz), plus line currents up to 37.2A at 380V (ND). The cabinet-mount design is IP20 and compact—H 495mm (580mm with EMC plate), W 211mm, D 232mm—at 13.5kg, suiting space-constrained panels. Engineers get fine control via an output frequency of 0.1…500Hz, 2…12kHz switching, 16 preset speeds, and independently adjustable ramps (0.01…9000s). I/O is sensor-ready: 3 analog inputs (0–10V / 0–20mA, including temperature/level probes), 2 analog outputs, 6 digital inputs (pulse to 30kHz), and 3 relay outputs (3A, 100k cycles) for interlocks/alarms. A 2-wire RS-485 Modbus RTU interface with RJ45 ensures seamless PLC/SCADA integration and diagnostics.

Trusted in harsh environments, this Schneider drive operates from −15…60°C and up to 95% RH (IEC60068-2-3), includes an integrated EMC filter (IEC61800-3 CatC3), and maintains a low 65dB noise profile. Comprehensive protections—thermal (motor/drive), overcurrent, short-circuit, over/undervoltage, phase loss, overspeed, and DC-bus events—safeguard uptime while DC-injection braking shortens stops on critical lines. For wiring ranges (control 0.5…1.5mm², power 10…16;mm²) and quick commissioning, the ATV610D18N4 simplifies standardization across utilities, water handling, HVAC, and process plants. For configuration details, see the ATV610D18N4 datasheet.