+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

Phoenix PLC-RPT- 24UC/21/RW Relay Module

The Phoenix PLC-RPT- 24UC/21/RW Relay Module (Part No: 2900318 ) offers a 24 V DC nominal input voltage UN, 18.5 V DC ... 33.6 V DC input voltage range, polarized Drive, 4 ms typical response time. Manufactured by Phoenix under the Phoenix Relay Module category, this model belongs to the Phoenix PLC Series.

Phoenix Contact PLC-RPT- 24UC/21/RW 2900318
BrandPhoenix Contact
Product TypeRelay Module
Model NumberPLC-RPT- 24UC/21/RW

Phoenix PLC-RPT- 24UC/21/RW Relay Module – Technical Specifications

SpecificationValue
Product typeRelay Module
Product familyPLC-INTERFACE
ApplicationRailway applications
Mechanical service lifeapprox. 2x 107 cycles
Insulation-
Overvoltage categoryIII
Pollution degree2
Maximum power dissipation for nominal condition0.22 W
Test voltage (Winding/contact)4 kVrms (50 Hz, 1 min., winding/contact)
Test voltage (Changeover contact/changeover contact)-
Rated surge voltage6 kV
Nominal input voltage UN24 V DC
Input voltage range18.5 V DC ... 33.6 V DC
Drive and functionmonostable
Drive (polarity)polarized
Typical input current at UN9 mA
Typical response time4 ms
Typical release time4 ms
Protective circuitSurge protection; Freewheeling diode
Operating voltage displayYellow LED
Contact switching type1 changeover contact
Type of switch contactSingle contact
Contact materialAgSnO
Maximum switching voltage250 V AC/DC (Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules.)
Limiting continuous current6 A
Maximum inrush current10 A (4 s)
Min. switching current10 mA (12 V)
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
Switching capacity1 A (at 24 V, DC13)
Connection methodPush-in connection
Stripping length10 mm
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 14
Tightening torque-
Width6.2 mm
Height80 mm
depth94 mm
Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)
Degree of protection (Relay)RT III (Relay)
Degree of protection (Relay base)IP20 (Relay base)
Ambient temperature (operation)-40 °C ... 70 °C (Temperature class TX)
Ambient temperature (storage/transport)-40 °C ... 85 °C
TemperatureD
HumidityA
VibrationB/C
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board
Low Voltage DirectiveConformance with Low Voltage Directive
Electromagnetic compatibilityConformance with EMC directive
Standards/regulationsIEC 60947-5-1
Mounting TypeDIN rail mounting
Mounting positionany
Contact Connection type-
Output fuse4 A gL/gG NEOZED
Degree of protection (Installation location)-
Mail Us for your needs in Phoenix Contact 1 Changeover Relay Module PLC-RPT- 24UC/21/RW part no: 2900318 with budget-friendly prices. The Main Technical Parameters of PLC-RPT- 24UC/21/RW, 2900318 inludce Relay Module type and PLC-INTERFACE Product family a versatile solution for Railway applications applications. This relay module features a mechanical service life of approx. 2x 107 cycles, ensuring durability and reliability. With a maximum power dissipation of 0.22 W, it operates efficiently at a nominal input voltage of 24 V DC, within an input voltage range of 18.5 V DC ... 33.6 V DC. The module has a typical input current of 9 mA at UN, with a response time of 4 ms and a release time of 4 ms. It is equipped with a Surge protection; Freewheeling diode for protection and includes 1 changeover contact made from Push-in connection Connection method. Customize Your Experience with a Quote for your requirement of Phoenix Contact 1 Changeover Relay Module. Experience the difference with our competitive pricing and superior support over other Suppliers.