Procurement teams shortlist UB500-18GM75-I-V15 with P&F Photoelectric Sensor, Pepperl Fuchs Uc2000 30Gm Iur2 V15 and Banner Ultrasonic Sensor, aligning budget approvals, warranty terms, and multisite availability for smoother rollout across plants.
Pepperl Fuchs UB500-18GM75-I-V15 Ultrasonic Sensor
The Pepperl Fuchs UB500-18GM75-I-V15 Ultrasonic Sensor offers a Cylindrical design, 30 ... 500 mm
sensing range, 1 analog output 4 ... 20 mA output, and Connector plug M12 x 1 , 5-pin
connection. Manufactured by Pepperl Fuchs under the P&F Ultrasonic Sensor category, this model belongs to the diffuse reflective sensor.

| Brand | Pepperl Fuchs |
| Product Type | Ultrasonic Sensor |
| Model Number | UB500-18GM75-I-V15 |
Pepperl Fuchs UB500-18GM75-I-V15 Ultrasonic Sensor β Technical Specifications
| Specification | Value |
|---|---|
| Type of Sensing | Diffuse Reflective |
| Design | Cylindrical |
| Sensing range | 30 ... 500 mm |
| Adjustment range | 50 ... 500 mm |
| Dead band | 0 ... 30 mm |
| Standard target plate | 100 mm x 100 mm |
| Transducer frequency | approx. 380 kHz |
| Response delay | approx. 50 ms |
| LED green | - |
| LED yellow 1 | solid yellow: object in the evaluation range yellow, flashing: program function, object detected |
| LED yellow 2 | - |
| LED red | solid red: Error red, flashing: program function, object not detected |
| Operating voltage | 10 ... 30 V DC , ripple 10 %SS |
| Output type | 1 analog output 4 ... 20 mA |
| Default setting | - |
| Repeat accuracy | Β± 0.1 % of full-scale value |
| Switching frequency | - |
| Range hysteresis | - |
| Temperature influence | Β± 1.5 % of full-scale value |
| Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
| UL approval | cULus Listed, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated β€36 V |
| Ambient temperature | -25 ... 70 Β°C (-13 ... 158 Β°F) |
| Storage temperature | -40 ... 85 Β°C (-40 ... 185 Β°F) |
| Connection type | Connector plug M12 x 1 , 5-pin |
| Degree of protection | IP67 |
| Material Housing | brass, nickel-plated |
Talk to Our Engineer for Pepperl and Fuchs Ultrasonic Sensor UB500-18GM75-I-V15 with exclusive offers. Core System Specifications of UB500-18GM75-I-V15 are Diffuse Reflective, Cylindrical design with a sensing range of 30 ... 500 mm
and an adjustment range of 50 ... 500 mm
. It has a dead band of 0 ... 30 mm
and uses a standard target plate of 100 mm x 100 mm. The transducer frequency is approximate approx. 380 kHz
, and the response delay of approx. 50 ms
. Operating at 10 ... 30 V DC , ripple 10 %SS
, the sensor includes 1 analog output 4 ... 20 mA. It offers repeat accuracy of Β± 0.1 % of full-scale value a temperature influence of Β± 1.5 % of full-scale value. The sensor operates in ambient temperatures from -25 ... 70 Β°C (-13 ... 158 Β°F)
and can be stored in temperatures from -40 ... 85 Β°C (-40 ... 185 Β°F)
. It feature Connector plug M12 x 1 , 5-pin
, an IP67 protection rating, and an brass, nickel-plated housing. Don't Miss Out on a Quote for your requirement of Pepperl and Fuchs Ultrasonic Sensor. Count on us for more economical pricing and more reliable support than other Dealers & Distributors.